Linear Range - TV Scenarios
TV screens above the linear range of replaces can be achieved in a number of ways. It is largely not
recommended to position a TV directly above any of the Lopi linear replaces due to the large amount of
radiant and convection heat produced, however it can be achieved in a number of suggested ways.
Building a TV recess/niche directly above the replace is restricted by the minimum enclosure height of
each replace so as an alternative a number of proposed set-up options to protect the TV are shown below.
Scenario 1 - Double Recess
In this scenario a wall is built out from the face of the replace by 100mm in depth and the TV recess is
created within the built out section above the replace. This is achieved by using the minimum mantel
clearances shown in the installation manual of each replace.