Casio EA-200 User's Manual

Download Operation & user’s manual of Casio E-Con EA-200 Calculator, Power Supply for Free or View it Online on All-Guides.com.

Brand: Casio

Category: Calculator , Power Supply , Software

Type: Operation & user’s manual for Casio E-Con EA-200

Pages: 55 (2.37 Mb)

Download Casio E-Con EA-200 Operation & user’s manual

Casio E-Con EA-200 Operation & user’s manual - Page 1
1
Casio E-Con EA-200 Operation & user’s manual - Page 2
2
Casio E-Con EA-200 Operation & user’s manual - Page 3
3
Casio E-Con EA-200 Operation & user’s manual - Page 4
4
Casio E-Con EA-200 Operation & user’s manual - Page 5
5
Casio E-Con EA-200 Operation & user’s manual - Page 6
6
Casio E-Con EA-200 Operation & user’s manual - Page 7
7
Casio E-Con EA-200 Operation & user’s manual - Page 8
8
Casio E-Con EA-200 Operation & user’s manual - Page 9
9
Casio E-Con EA-200 Operation & user’s manual - Page 10
10
Casio E-Con EA-200 Operation & user’s manual - Page 11
11
Casio E-Con EA-200 Operation & user’s manual - Page 12
12
Casio E-Con EA-200 Operation & user’s manual - Page 13
13
Casio E-Con EA-200 Operation & user’s manual - Page 14
14
Casio E-Con EA-200 Operation & user’s manual - Page 15
15
Casio E-Con EA-200 Operation & user’s manual - Page 16
16
Casio E-Con EA-200 Operation & user’s manual - Page 17
17
Casio E-Con EA-200 Operation & user’s manual - Page 18
18
Casio E-Con EA-200 Operation & user’s manual - Page 19
19
Casio E-Con EA-200 Operation & user’s manual - Page 20
20
Casio E-Con EA-200 Operation & user’s manual - Page 21
21
Casio E-Con EA-200 Operation & user’s manual - Page 22
22
Casio E-Con EA-200 Operation & user’s manual - Page 23
23
Casio E-Con EA-200 Operation & user’s manual - Page 24
24
Casio E-Con EA-200 Operation & user’s manual - Page 25
25
Casio E-Con EA-200 Operation & user’s manual - Page 26
26
Casio E-Con EA-200 Operation & user’s manual - Page 27
27
Casio E-Con EA-200 Operation & user’s manual - Page 28
28
Casio E-Con EA-200 Operation & user’s manual - Page 29
29
Casio E-Con EA-200 Operation & user’s manual - Page 30
30
Casio E-Con EA-200 Operation & user’s manual - Page 31
31
Casio E-Con EA-200 Operation & user’s manual - Page 32
32
Casio E-Con EA-200 Operation & user’s manual - Page 33
33
Casio E-Con EA-200 Operation & user’s manual - Page 34
34
Casio E-Con EA-200 Operation & user’s manual - Page 35
35
Casio E-Con EA-200 Operation & user’s manual - Page 36
36
Casio E-Con EA-200 Operation & user’s manual - Page 37
37
Casio E-Con EA-200 Operation & user’s manual - Page 38
38
Casio E-Con EA-200 Operation & user’s manual - Page 39
39
Casio E-Con EA-200 Operation & user’s manual - Page 40
40
Casio E-Con EA-200 Operation & user’s manual - Page 41
41
Casio E-Con EA-200 Operation & user’s manual - Page 42
42
Casio E-Con EA-200 Operation & user’s manual - Page 43
43
Casio E-Con EA-200 Operation & user’s manual - Page 44
44
Casio E-Con EA-200 Operation & user’s manual - Page 45
45
Casio E-Con EA-200 Operation & user’s manual - Page 46
46
Casio E-Con EA-200 Operation & user’s manual - Page 47
47
Casio E-Con EA-200 Operation & user’s manual - Page 48
48
Casio E-Con EA-200 Operation & user’s manual - Page 49
49
Casio E-Con EA-200 Operation & user’s manual - Page 50
50
Casio E-Con EA-200 Operation & user’s manual - Page 51
51
Casio E-Con EA-200 Operation & user’s manual - Page 52
52
Casio E-Con EA-200 Operation & user’s manual - Page 53
53
Casio E-Con EA-200 Operation & user’s manual - Page 54
54
Casio E-Con EA-200 Operation & user’s manual - Page 55
55
20020601
English
Activity: Operating the EquipmentActivity: Operating the Equipment
MeasurementMeasurement
2-11-2
u As shown in the illustration, force water through the reflux condenser.
u For boiling point elevation, turn on the heater and use the Temperature Measurement
Setup to measure the temperature.
u For freezing point depression, turn on the auto stirrer and use the Temperature
Measurement Setup to measure the temperature.
u Use the measured changes in temperature to determine boiling point elevation and
freezing point depression.
u Compare the measured results with the results calculated from naphthalene molality.
55555555555555555555555
5555555555555555555555
5555555
Other Things To Do
5555555
Measuring Data
u Measure the mass of the beaker used for creating the solution.
u Slowly pour the benzene into the beaker so it flows down the inside surface of the beaker.
u Measure the mass of the small amount of naphthalene being used.
u Dissolve the small amount of naphthalene to create a dilute benzene solution, and then
measure the mass of the solution.
u Calculate the molality of the naphthalene.
u Divide the dilute benzene solution between two flasks, pouring the solution slowly along
the inside surfaces of the flasks.
u Secure one of the flasks in the boiling point elevation system, and the other one in the
freezing point depression system.
Calculator Operation
u Perform the following operation to prepare for temperature measurement using the
Temperature Measurement Setup.
Using E-CON
Using a Calculator Program
Find the applicable program in the Program Library (P.2-16-3), input it into your calculator,
and then run it.
u Display a graph of temperature change starting from the point that the solution is first
heated.
T(°C) : Temperature
t(s) : Time
T
1
(°C): Solution Boiling Point
u Display a graph of temperature change starting from the point that the solution is first
cooled.
T(°C) : Temperature
t(s) : Time
T
2
(°C): Solution Freezing Point
1 Benzene
2 Naphthalene
3 Beaker
4 Round Bottom Flask
5 Naphthalene-Benzene
Solution
u Consider how the molecular weight of naphthalene can be determined using the
measurement results.
u Consider why the cooling curve of freezing point depression is not clear.
u Create another dilute solution using a different solute, and determine the boiling
point elevation and the freezing point depression.
u Create another dilute solution using a different solvent, and determine the boiling
point elevation and the freezing point depression.
1 Reflux Condenser
2 Ta p
3 Water Flow Direction
4 Open the tap.
For freezing point depression, use the mixing stick to stir the flask contents.
m“E-CON”w1(SETUP)b(Wizard)w
1(CASIO)c(TEMP)b(°C) 5w240w1(YES)