Honeywell OmniClass OM15 Installation Manual

Download Installation manual of Honeywell OmniClass OM41 Card Reader for Free or View it Online on All-Guides.com. This version of Honeywell OmniClass OM41 Manual compatible with such list of devices, as: OmniClass OM41, OmniClass OM16, OmniClass OM31, OmniClass OM43, OmniClass OM56

Honeywell OmniClass  OM41 Installation manual - Page 1
1
Honeywell OmniClass  OM41 Installation manual - Page 2
2
Honeywell OmniClass  OM41 Installation manual - Page 3
3
Honeywell OmniClass  OM41 Installation manual - Page 4
4
Honeywell OmniClass  OM41 Installation manual - Page 5
5
Honeywell OmniClass  OM41 Installation manual - Page 6
6
Honeywell OmniClass  OM41 Installation manual - Page 7
7
Honeywell OmniClass  OM41 Installation manual - Page 8
8
Honeywell OmniClass  OM41 Installation manual - Page 9
9
Honeywell OmniClass  OM41 Installation manual - Page 10
10
Honeywell OmniClass  OM41 Installation manual - Page 11
11
Honeywell OmniClass  OM41 Installation manual - Page 12
12
Honeywell OmniClass  OM41 Installation manual - Page 13
13
Honeywell OmniClass  OM41 Installation manual - Page 14
14
INSTALLATION GUIDE
This Installation Guide is for informational purposes only. Honeywell makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are ctitious.
Specications are subject to change without notice.
PLT-01558, Rev A.1
PLT-01558, Rev A.1INSTALLATION GUIDE Page 1
Parts
1 – OmniClass Reader
1 – Installation Guide
2 – #6-32 x .375” Phillips machine screws
3 – #6-32 x .375” spanner security screw
2 – 7-pin Terminal connectors for terminal readers
1 – 10-pin Terminal connector
Recommended
Cable, 5-9 conductor (Wiegand or Clock-and-Data), 4 conductor Twisted Pair Over-All Shield and UL
approved, Belden3107A or equivalent (OSDP)
Linear DC power supply
Metal or plastic junction box
Security tool (for anti-tamper screw) HID 04-0001-03
Drill with various bits for mounting hardware
Mounting hardware
Reader spacer when mounting on or near metal or metal junction boxes - see How to Order Guide
IP65 Mounting gasket, recommended for outdoor installation
Back box
Specication
PRODUCT
BASE PART
NUMBER
INPUT
VOLTAGE (VDC)
CURRENT
1
OPERATING
TEMPERATURE
5
CABLE LENGTH
6
REGULATORY
REF NUMBER
STANDBY
AVG
2
MAX AVG
3
PEAK
4
OM30/OM32 (R10)
7
900N
5 - 16VDC
60mA 95mA
200mA
-30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand = 500 ft - 22 AWG (152 m)
300 ft - 24 AWG 91 m)
RS-485 = Max bus length
4000 ft - 24 AWG (1,219 m)
Max length between nodes:
1640 ft - 24 AWG (500m)
R10Ex
1
x
2
x
3
OM31/OM33 (RP10)
7
900P
75mA 100mA
RP10Ex
1
x
2
x
3
OM15/OM17 (R15)
7
910N 60mA 95mA R15Ex
1
x
2
x
3
OM16/OM18 (RP15)
7
910P 75mA 100mA RP15Ex
1
x
2
x
3
OM40/OM42 (R40)
7
920N 65mA 95mA R40Ex
1
x
2
x
3
OM41/OM43 (RP40)
7
920P 85mA 100mA RP40Ex
1
x
2
x
3
OM55/OM57 (RK40)
7
921N
5.5 - 16VDC
85mA 100mA
220mA
RK40Ex
1
x
2
x
3
OM56/OM58 (RPK40)
7
921P
95mA 105mA
RPK40Ex
1
x
2
x
3
Bluetooth Specications
OPERATING TEMPERATURE FREQUENCY FCC & IC IDS
-15° to 150° F (-25° to 65° C) 2.4 - 2.480 GHz
FCC-ID: JQ6-ICLASSBTM
IC-ID: 2236B-ICLASSBTM
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module is installed inside
another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains Transmitter Module with FCC ID JQ6-
ICLASSBTM and IC ID 2236B-ICLASSBTM”.
1 Communication protocols other than Wiegand or Clock & Data (for control
panels), as well as credential interfaces over BLE (not applicable for 9xxL
models), require an additional hardware module which increases current
by 40mA.
2 Standby AVG - RMS current draw without a card in the RF eld.
3 Maximum AVG - RMS current draw during continuous card reads. Not
evaluated by UL.
4 Peak - highest instantaneous current draw during RF communication.
5 When congured for Bluetooth Operating Range is -13° to 150° F
(-25° to 65° C)
6 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
7 Mobile Enabled Products, see specications below.
UL Reference Number Deciphering
x
1
Reader Colors: K = Black
x
2
Wiring: N = Pigtail
T = Terminal
5 = 5 meter Pigtail
x
3
Communications: N = No Module
R = RS-485 (OSDP)
L = Indala Prox
B = Bluetooth