quickstart guide
DM-MD6X4/DM-MD6X6
www.crestron.com
888.273.7876 201.767.3400
Specifications subject to
change without notice.
QUICKSTART DOC. 7218B (2031226) 06.17
DigitalMedia™ Distribution Center
For more information, refer to the latest version of the
DM-MD6X4/DM-MD6X6 Installation & Operation Guide, Doc. 7196.
DM-MD6X4/DM-MD6X6
1
Connections
1
To connect the Crestron
®
DM-MD6X4 or DM-MD6X6, refer to
the information below and to the illustration to the right.
(The DM-MD6X6 rear panel is shown.)
HDMI
®
Input Connections
Using HDMI cables, connect up to six HDMI digital
video/audio input devices to the HDMI input
connectors (HDMI 1 to HDMI 6).
HDMI Output Connection
Using an HDMI cable, connect an HDMI digital
video/audio output device to the HDMI output connector
(HDMI 1).
DM 8G+
®
Output Connections
Connect up to three (DM-MD6X4) or five (DM-MD6X6)
Crestron DigitalMedia 8G+
®
receivers/room controllers to
the DM 8G+ output connectors (DM 2 to DM 4 on the
DM-MD6X4 or DM 2 to DM 6 on the DM-MD6X6).
Connections can also be made to HDBaseT
®
Alliance
Certified display devices without requiring any
DM
®
receivers. (The illustration to the right shows
connections to DM-RMC-4K-100-C devices.)
For DM 8G+ or HDBaseT wiring up to 330 feet
(100 meters) between devices, use Crestron DM-CBL-8G
DigitalMedia 8G™ cable or generic CAT5e (or better)
UTP or STP.
USB HID Connection
Using a USB cable with a type B female connector,
connect a host computer or other USB HID compliant
host to the USB HID connector (USB-HID).
LAN Connection
Using an RJ-45 cable, connect the 8-pin LAN port to the
10BASE-T/100BASE-TX Ethernet network.
Power Connection
Connect one end of the included power cord to the
DM-MD6X4 or DM-MD6X6
and the other end to the ac
power source.
Configuration
2
NOTE: The DM-MD6X4 and DM-MD6X6 do not have
a power switch. Power is applied to the unit when the
supplied power cord is connected to the ac power
source.
NOTE: Shielded cable and connectors are
recommended to safeguard against unpredictable
environmental electrical noise that may impact
performance at resolutions above 1080p.
A. Access Installer Mode
1. Ensure that the home screen is
displayed. If it is not displayed, press
the HOME button. The home screen
is shown to the right.
2. Press the BACK button.
The Installer password screen
appears.
3. Enter the four-digit password. (The
default password is “1234”.) To enter
a digit, do either of the following:
Use the front panel controls to configure the DM-MD6X4 or DM-MD6X6.
Home Screen
(DM-MD6X6 Shown)
Installer Password
Screen
If the digit ranges from 1–6, press
the appropriate INPUT or OUTPUT
button that corresponds to the digit
to be entered.
If the digit is 0 or ranges from 7–9, use the navigation pad as follows:
Press the Up or Down navigation button as necessary until the desired
digit appears between the brackets, and then press the Select button.
Down
Left
Up
Right
Select
Navigation Pad
B. Set Input and Output Names (Optional)
For inputs 1–6, the default names are Input 1, Input 2, and so on.
For outputs 1–4 (DM-MD6X4) or outputs 1–6 (DM-MD6X6), the default names
are Output 1, Output 2, and so on.
Use the following procedure to change an input name:
1. In the Installer menu, navigate to Inputs if it
is not already highlighted, and then press the
Select button on the navigation pad.
The Input submenu appears for the currently
selected input. The name of the input
is shown at the top of the Input submenu.
(The LED of the currently selected input lights.)
2. Select the desired input by pressing the
appropriate INPUT button (16).
The LED of the selected input lights, and
the name of the input appears at the top of the
Input submenu.
3. Navigate to Name if it is not already highlighted, and then press the
Select button.
A scrollable list of predefined source names appears for the input.
4. Navigate to the desired source name in the list, and then press the
Select button to confirm the selection.
The selected name now appears at the top of the Input submenu for the
selected input.
After the fourth digit is correctly entered, the Installer menu appears.
Installer Menu
Input Submenu
(Input 1 Shown)
Use the following procedure to change an output name:
1. In the Installer menu, navigate to Outputs and then press the
Select button.
The Output submenu appears for the currently
selected output. The name of the output
is shown at the top of the Output submenu.
(The LED of the currently selected output lights.)
2. Select the desired output by pressing the
appropriate OUTPUT button (14 on the
DM-MD6X4 or 16 on the DM-MD6X6).
The LED of the selected output lights, and
the name of the output appears at the top of the
Output submenu.
3. Navigate to Name if it is not already highlighted, and then press the
Select button.
A scrollable list of predefined room names appears for the output.
4. Navigate to the desired room name in the list, and then press the
Select button to confirm the selection.
The selected name now appears at the top of the Output submenu for
the selected output.
Output Submenu
(Output 1 Shown)
After 30 seconds of inactivity,
the DM-MD6X4 and
DM-MD6X6 time out and return
to the home screen while
dimming the LCD.
HD cable
Blu-Ray
Disc® player
Computer
Display
HD cable
DM-RMC-4K-100-C
Display
AC power
LAN
PROCISE®
surround
system
DM-MD6X6
Ground