Bosch B465 Quick Start Manual

Download Quick start manual of Bosch B465 Cell Phone for Free or View it Online on All-Guides.com.

Brand: Bosch

Category: Cell Phone

Type: Quick start manual for Bosch B465

Pages: 2

Download Bosch B465 Quick start manual

Bosch B465 Quick start manual - Page 1
1
Bosch B465 Quick start manual - Page 2
2
1 | Overview
2 | Installation
This section describes basic hardware installation procedures
for installing the enclosure, B465 and B46 modules, and
knockout locations for wire routing. For information on
configuration, LED descriptions, and troubleshooting refer to
the
B465 Installation and Operation Guide (P/N: F01U311207).
CAUTION!
Remove all power (AC and battery) before making
any connections. Failure to do so might result in
personal injury and/or equipment damage.
NOTICE!
Notify the central station and the local authority
before installing the B465 in an existing system.
2
3
7
13
15
1
4
5
8
9
6
10
11
TMPR
BAT
ETHERNET
EXTERNAL
ANNUNC
X
MODULE 1
Y
MODULE
RELEASE
1 COM 2 3 COM 4
T R
PNL LINE 1
C NO
RELAY 2
16.5VAC
NC C NO
RELAY 1
TRBL
TX
RX
PWR
PANEL
LINE 2
USB
ETHERNET
100BASE-T
LINK
COMMUNICATION MODULE 1
3 COM 41 COM 2
R Y G B
SDI2
Device Bus
BATTERY
PANEL
LINE 1
BATTERY
POWER
RX
TX
SYSTEM TROUBLE
INPUTS
2.2 k End of
Line Resistors
C NO
RELAY 3
12V
AUX COM
16
1214
T R
PNL LINE 2
24 VDC
or
16.5 VAC
+ -
BATTERY
The B465 Conettix Universal Dual Path Communicator links the
digital dialer from a intrusion/fire control panel to an Ethernet
connection on a local area network (LAN) or wide area network
(WAN). The module uses its built-in Ethernet connection, and/or
a Conettix plug-in cellular module (B440/B441/B442/B443) to
send reports to the central station receiver.
Figure 1.1: Board overview
Callout ― Description Callout ― Description
1 ― Holes to stabilize plug-in
modules
9 ― Control panel phone line
connectors
2 ― Plug-in module connector 10 ― Input loop terminals
(COM 1 to COM 4)
3 ― Plug-in module retention clip 11 ― 12V AUX/COM terminal
4 ― Ethernet connector 12 ― Programmable output
relays to a control panel
5 ― USB connector 13 ― Heartbeat LED
6 ― Status LEDs (SYSTEM
TROUBLE, TX, RX, POWER, and
BATTERY)
14 ― 12 VDC sealed lead-acid
rechargeable battery terminals
7 ― External Annunciator
connector (connected to a B46)
15 ― Earth ground terminal
8 ― Tamper switch 16 ― 16.5 VAC or 24 VDC
power supply input terminals
2.1 | Remove enclosure knockouts
2.4 | Apply the wiring label into the enclosure
Apply the supplied wiring label to the inside, enclosure door.
Refer to Figure 2.3 for wiring label location.
Callout ― Description
1 ― Suggested knockout locations for B465 wiring
2 ― Knockouts for B46 LED cover and module (optional for non-fire
applications)
3 ― Lockset mounting knockout
Figure 2.1: Enclosure knockout locations (B10 shown)
1
1
1
1
3
2
4
2.3 | Mount the enclosure
Mount the UL Listed enclosure such as the B10/B10R, B11/
B11R, or D8103 enclosure in the desired location. Refer to
Figure 2.3.
2.5 | Insert enclosure earth ground wiring
Insert the supplied earth ground wire onto the inside clip of a
B10/B10R or B11/B11R the enclosure door. Refer to Figure 2.3
for ground wire location.
Review knockout locations before installing onto any surface.
Each enclosure is slightly different regarding knockout locations.
Use a hammer and punch to remove the desired knockout
locations. Use pliers to remove metal debris. Refer to Figure 2.1.
Callout ― Description
1 ― B10/B10R enclosure
2 ― B11/B11R enclosure
3 ― Mounting plastic standoff locations for B465
Figure 2.5: Mount the module
2
3
3
1
2
3
3
3
3
4
5
Figure 2.3: Mount the enclosure (B10/B10R shown)
Callout ― Description
1 ― B465 wiring label (label insertion location)
2 ― Earth ground wiring enclosure location
3 ― Enclosure mounting holes (4)
4 ― B46 mounting locations*
5 ― Tamper switch mounting locations (optional)
* Use the upper, right-hand 3-hole mounting location for installing the optional B46
module in a B10 enclosure.
2.6 | Insert plastic standoff
Snap the four supplied plastic standoffs onto four enclosure
support posts. Refer to Figure 2.4. and Figure 2.5.
Figure 2.4: Mount the plastic standoff onto the enclosure
Callout ― Description
1 ― Module with mounting bracket installed
2 ― Enclosure (side wall)
3 ― Mounting screws (3)
Figure 2.7: Mount the B46 module
1
3
2
Callout ― Description
1 ― B46
2 ― Enclosure
Figure 2.8: Installing into an enclosure
2
1
2.8 | Mount the B46 module (optional)
Mount the B46 into the enclosure’s side, 3-hole mounting
pattern using the supplied mounting screws, and
secure onto the enclosure. Refer to Figure 2.7. For more
information on the B46 installation, refer to the B46
Installation and Operation Guide (P/N: F01U312441).
2.7 | Inserting the screws
Mount the B465 into the enclosure’s 4-hole plastic standoffs
using the supplied screws and a slotted screwdriver. Refer
to Figure 2.6.
Figure 2.6: Mount the enclosure
NOTICE!
The SDI2 Device Bus terminal connector located