Mitsubishi Electric GT1675M-STBA General Description

Download General description of Mitsubishi Electric 1D7MP6 Control Unit, Touch terminals for Free or View it Online on All-Guides.com. This version of Mitsubishi Electric 1D7MP6 Manual compatible with such list of devices, as: 1D7MP6, GT1665M-STBA, GT1665M-STBD, GT1675-VNBA, GT1675M-VTBD

Mitsubishi Electric 1D7MP6 General description - Page 1
1
Mitsubishi Electric 1D7MP6 General description - Page 2
2
GT16 General Description
Thank you for purchasing the GOT1000 Series.
GT1695M-XTBA
GT1675M-STBA
GT1675-VNBA
GT1665M-STBA
GT1662-VNBA
GT1695M-XTBD
GT1675M-STBD
GT1675-VNBD
GT1665M-STBD
GT1662-VNBD
GT1685M-STBA
GT1675M-VTBA
GT1672-VNBA
GT1665M-VTBA
GT1655-VTBD
GT1685M-STBD
GT1675M-VTBD
GT1672-VNBD
GT1665M-VTBD
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL GT16-U-GD-E
Model
code
1D7MP6
IB(NA)-0800544ENG-A(1410)MEE
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Some failures of the GOT, communication unit or cable may keep the outputs
on or off.
Some failures of a touch panel may cause malfunction of the input objects
such as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
For bus connection : The CPU becomes faulty and the GOT becomes
inoperative.
For other than bus connection : The GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious
accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
WARNING
CAUTION
WARNING
[DESIGN PRECAUTIONS]
[DESIGN PRECAUTIONS]
[MOUNTING PRECAUTIONS]
Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out.
When the GOT backlight goes out, although the POWER LED blinks (green/
orange) and the display section dims, the input of the touch switch(s) remains
active.
This may confuse an operator in thinking that the GOT is in "screensaver"
mode, who then tries to release the GOT from this mode by touching the
display section, which may cause a touch switch to operate.
Note that the following occurs on the GOT when the backlight goes out.
• GT1655-V: The POWER LED blinks (green/orange) and the monitor screen
appears blank.
• Models other than GT1655-V: The POWER LED blinks (green/orange) and
the monitor screen appears dimmed.
The display section of the GT16 is an analog-resistive type touch panel.
If you touch the display section simultaneously in 2 points or more, the switch
that is located around the center of the touched point, if any, may operate.
Do not touch the display section in 2 points or more simultaneously.
Doing so may cause an accident due to incorrect output or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT or shut off the
power of the GOT at the same time.
Not doing so can cause an accident due to false output or malfunction.
Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm apart.
Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or
driver.
Doing so can result in a damage or failure of the display section.
When the GOT is connected to the Ethernet network, the available IP
address is restricted according to the system configuration.
• When multiple GOTs are connected to the Ethernet network:
Do not set the IP address (192.168.0.18) for the GOTs and the controllers in
the network.
• When a single GOT is connected to the Ethernet network:
Do not set the IP address (192.168.0.18) for the controllers except the GOT
in the network.
Doing so can cause the IP address duplication. The duplication can
negatively affect the communication of the device with the IP address
(192.168.0.18).
The operation at the IP address duplication depends on the devices and the
system.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the communication unit, option function
board onto/from the GOT.
Not doing so can cause the unit to fail or malfunction.
When installing the option function board, wear an earth band etc. to avoid
the static electricity.
Not doing so can cause a unit corruption.
Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product
damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 to 0.48 N•m) with a Phillips-head screwdriver
No.2.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or the GOT.
When loading the communication unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the specified torque
range (0.36 to 0.48 N•m) with a Phillips-head screwdriver No.2.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
When mounting the option function board onto the GOT, connect it to the
corresponding connector securely and tighten the mounting screws within the
specified torque range (0.25 to 0.35 N•m) with a Phillips-head screwdriver
No.1.
Undertightening can cause malfunction due to poor contact.
Overtightening can cause malfunction due to screw or unit damage.
When inserting a CF card into the GOT, push it into the insertion slot until the
CF card eject button will pop out.
If not properly inserted, a bad connection may cause a malfunction.
When inserting/removing a CF card into/from the GOT, turn the CF card
access switch off in advance.
Failure to do so may corrupt data within the CF card.
When removing a CF card from the GOT, make sure to support the CF card
by hand, as it may pop out.
Failure to do so may cause the CF card to drop from the GOT and break.
WARNING
CAUTION
WARNING
CAUTION
[MOUNTING PRECAUTIONS]
[WIRING PRECAUTIONS]
[TEST OPERATION PRECAUTIONS]
[STARTUP/MAINTENANCE PRECAUTIONS]
When installing a USB memory to the GOT, make sure to install the USB
memory to the USB interface firmly.
Failure to do so may cause a malfunction due to poor contact.
Before removing the USB memory from the GOT, operate the utility screen
for removal. After the successful completion dialog box is displayed, remove
the memory by hand carefully.
Failure to do so may cause the USB memory to drop, resulting in a damage
or failure of the memory.
For closing the USB environmental protection cover, fix the cover by pushing
the mark on the latch firmly to comply with the protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may
not be removed.
Operate and store the GOT in environments without direct sunlight, high
temperature, dust, humidity, and vibrations.
When using the GOT in the environment of oil or chemicals, use the
protective cover for oil.
Failure to do so may cause failure or malfunction due to the oil or chemical
entering into the GOT.
Be sure to shut off all phases of the external power supply used by the
system before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
Always ground the FG terminal, LG terminal, and Functional ground terminal
of the GOT power to the protective ground conductors dedicated to the GOT.
Not doing so may cause an electric shock or malfunction.
When tightening the terminal screws, use a Phillips-head screwdriver No.2.
Terminal screws which are not to be used must be tightened always at torque
0.5 to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless
terminals.
Use applicable solderless terminals and tighten them with the specified
torque.
If any solderless spade terminal is used, it may be disconnected when the
terminal screw comes loose, resulting in failure.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 to 0.8 N•m). Undertightening can cause a short circuit or
malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.
Before starting system operation, be sure to peel this label because of heat
dissipation.
Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
Plug the QnA/ACPU/Motion controller(A series) bus connection cable by
inserting it into the connector of the connected unit until it "clicks".
After plugging, check that it has been inserted snugly.
Not doing so can cause a malfunction due to a contact fault.
Before performing the test operations of the user creation monitor screen
(such as turning ON or OFF bit device, changing the word device current
value, changing the settings or current values of the timer or counter, and
changing the buffer memory current value), read through the manual
carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system.
False output or malfunction can cause an accident.
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Correctly connect the battery connector.
Do not perform the following actions to the battery.
• Charging, disassembling, heating, short-circuiting, or soldering the battery,
or throwing it into the fire
Doing so will cause the battery to produce heat, explode, or ignite, resulting in
injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.
Not switching the power off in all phases can cause a unit failure or
malfunction.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
CAUTION
WARNING
CAUTION
WARNING
WARNING
[STARTUP/MAINTENANCE PRECAUTIONS]
[TOUCH PANEL PRECAUTIONS]
[BACKLIGHT CHANGING PRECAUTIONS]
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the
cable portion.
Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
Do not drop the module or subject it to strong shock. A module damage may
result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the
battery.
If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Replace battery with GT15-BAT or GT11-50BAT by Mitsubishi electric
Co.only.
Use of another battery may present a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children.Do not disassemble and do not dispose of in fire.
For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position
may occur as the period of use elapses. When any difference between a
touched position and the object position occurs,execute the touch panel
calibration.
When any difference between a touched position and the object position
occurs, other object may be activated. This may cause an unexpected
operation due to incorrect output or malfunction.
Before changing the backlight, always switch off the GOT power externally in
all phases (when the GOT is connected to the bus, the PLC CPU power must
also be switched off externally in all phases) and remove the GOT from the
control panel.
Not switching the power off in all phases may cause an electric shock.
Not removing the unit from the control panel can cause injury due to a drop.
When replacing the backlight, use the gloves.
Otherwise, it may cause you to be injured.
Start changing the backlight more than 5 minutes after switching the GOT
power off.
Not doing so can cause a burn due to the heat of the backlight.
When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to
the local regulations.
(Refer to the User's Manual for the GOT you are using for details of the
battery directive in the EU member states.)
When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the User's Manual for the GOT you are using for details of the
regurated models.)
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of the User's Manual, as
they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden
packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other
than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
CAUTION
CAUTION
WARNING
CAUTION
CAUTION
CAUTION
Manual
The following shows manuals relevant to this product.
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the
drawing software used.
For relevant manuals, refer to the Help or the PDF manuals stored in the DVD-
ROM for the drawing software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (http://www.MitsubishiElectric.co.jp/fa/).
© 2014MITSUBISHI ELECTRIC CORPORATION
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
For details on GT16 specifications, installing procedure, EMC Directive, wiring,
maintenance and inspection, or checking method for the version and the
compatible standard, refer to GT16 User's Manual (Hardware).
Packing List
The GOT product package includes the following:
1. FEATURES
(1) Improved monitoring performance and connectivity to FA devices
GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S,
GT1665M-V, GT1655-V: The TFT color liquid crystal display (high intensity,
wide angle view, and high definition type) provides clear full-color display
and displays small characters clearly.
(Displays digital images of BMP and other formats in 65536 colors.)
GT1675-VN, GT1672-VN, GT1662-VN: The TFT color liquid crystal display
provides 4096 or 16 colors to offer a wide range of models that meet user
requirements.
Provides multi-language display function based on Unicode2.1 True Type
font and high-speed drawing of beautiful text.
High speed monitoring through high speed communication at maximum of
115.2kbps.
High speed display and high speed touch switch response.
The operation performance is improved by the analog touch panel.
GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S,
GT1665M-V: Applicable to a video/RGB unit and a multimedia unit
(2) More efficient GOT operations including screen design, startup, adjustment,
management and maintenance works
GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S,
GT1665M-V, GT1655-V: 15MB user memory is included as standard.
GT1675-VN, GT1672-VN, GT1662-VN: 11MB user memory is included as
standard.
Interfaces are included as standard. (Ethernet, RS-232, RS-422/485, CF
card, and USB)
Font installation is available to increase the system fonts.
Combined use of 4 types of alarms (system alarm, user alarm, alarm
history, alarm popup display) realizes more efficient alarm notification.
Maintenance timing report function is available that measures the backlight
energization time and notifies of maintenance time.
Detailed Manual
Manual name
Manual number
(Model code)
GT16 User's Manual (Hardware)
(Sold separately)
SH-080928ENG
(1D7MD3)
GT16 User's Manual (Basic Utility)
(Sold separately)
SH-080929ENG
(1D7MD4)
Relevant Manuals
Model name Product Quantity
GT1695M-X
GOT 1
Battery (GT15-BAT) 1
Installation fitting 8
GT16 General Discription 1
GT16 本体概要説明書
1
GT1685M-S
GT1675M-S
GT1675M-V
GT1675-VN
GT1672-VN
GT1665M-S
GT1665M-V
GOT 1
Battery (GT15-BAT) 1
Installation fitting 4
GT16 General Discription 1
GT16 本体概要説明書
1
GT1655-V
GOT 1
Battery (GT11-50BAT) 1
Installation fitting 4
GT16 General Discription 1
GT16 本体概要説明書
1
The USB interface is positioned on the GOT front. This enables the system
startup to be performed more efficiently using FA device startup tool, and
eliminates the necessity of indirect works (opening and closing the control
panel, cable replacement, cable rewiring) in order to improve the working
efficiency.
The blown backlight bulb can be confirmed even during screen saving, with
the blinked POWER LED at backlight shutoff detection.
(3) Enhanced support of FA device setup tools
Transferring and monitoring sequence programs with the personal computer
connected to the GOT can be executed when connecting to a PLC CPU
with the direct CPU connection or bus connection. (FA transparent function)
2. Part Names and Settings
Part Names and Settings of the GT16
*1: No video/RGB interface on the GT1675-VN, GT1672-VN, GT1662-VN, and
GT1655-V.
*2: Battery holder for the GT1665 and GT1662.
*3: No extension interface 2 on the GT1655.
*4: Located on the extension interface 2 on the GT1655.
*5:Integral with the CF card interface cover for the GT1655.
*6:No human sensor on the GT1675, GT1672, GT1665, GT1662, and GT1655.
*7:No LG terminal on the GT1655.
*8:On the rear face of the GT1655, the functional ground terminal is located on the
left side of the FG terminal.
No. Name Description
1) POWER LED
Lit in green : Power is correctly supplied , Lit in orange :
Screen saving
Blinks in orange/green : Blown back light bulb , Not lit :
Power is not supplied
2) Display screen Displays the Utility and the user creation screen.
3) Touch key
For operating touch switches in the Utility and the user
creation screen
4) USB interface (Device)
For connecting a personal computer (Connector type: Mini-
B)
5) USB interface (Host)
For USB mouse/keyboard ,data transfer and storage
(Connector type: TYPE-A)
6) RS-232 interface
For communicating with a controller or connecting a
personal computer(Connector type: D sub 9-pin)
7) Ethernet interface
For communicating with a controller or using the gateway
function (Connector type: RJ-45 (modular jack))
8) RS-422/485 interface
For communicating with a controller (Connector type: 14-pin
(female))
9) Power terminal
*8
Power input terminal, LG terminal
*7
, FG terminal
10) Extension interface1 For installing an extension unit (I/F-1)
11) Extension interface2
*3
For installing an extension unit (I/F-2)
12) CF card interface For installing a CF card
13) CF card access LED Lit : CF card accessed , Not lit : CF card not accessed
14) CF card access switch
Used for accepting or stopping the access to the CF card
before removing the CF card from the GOT
ON :CF card being accessed (CF card removal
prohibited)
OFF :CF card not accessed (CF card removal possible)
15) Video/RGB interface
*1
For mounting the video input unit, RGB input unit, video/
RGB input unit, RGB output unit, or multimedia unit
16)
Terminating resistor
setting switch
For switching on and off of the terminating resistor for the
RS-422/485 communication port
17)
Optional function
board interface
*4
For installing the optional function board
18) Reset switch
Hardware reset switch (Inoperative in the bus connection or
with the bus connection unit installed)
19)
Hole for unit
installation fitting
Hole for inserting the unit installation fitting
20) Battely cover
*2*5
Houses the battery
21) Human sensor
*6
Sensor that detects human movement
22) Installation switch Used for OS installations at the GOT startup
GOT
Rear face
20)
12)
13)
14)
21)
1)
4)
5)
2),3)
19)
6) 7) 8)
9)
10) 11)
18)
17) 16)
15)
22)
Example)
GT1695
19)
19)
3. Specifications
3.1 General Specifications
*1: When mounting a multimedia unit (GT16M-MMR), MELSECNET/H
communication unit (GT15-J71LP23-25, GT15-J71BR13), or CC-Link
communication unit (GT15-J61BT13), the operating ambient temperature must
be reduced 5 °C against the maximum values described in general
specifications.
Lors du montage d'un module multimédia (GT16M-MMR), du module de
communication MELSECNET/H (GT15-J71LP23-25, GT15-J71BR13) ou du
module de communication CC-Link (GT15-J61BT13), la température ambiante
de fonctionnement doit être réduite de 5°C par rapport aux valeurs maximales
décrites dans les spécifications générales.
*2: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a
malfunction.
When an air purge is made inside the control panel by adding pressure, there
may be a clearance between the surface sheet and the screen making it difficult
to use the touch panel, or the sheet may come off.
*3: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*4: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT16.
3.2.1 For GOTs powered from the 100 to 240VAC
power supply
Item Specifications
Operating
ambient
temperature
*1
Température
ambiante de
fonctionnem
ent
*1
Display
section
Zone
d'affichage
0 to 50
0 à 50
Other than
the display
section
Autre que la
zone
d'affichage
0 to 55
0 à 55
Storage ambient
temperature
-20 to 60
Operating ambient
humidity
10 to 90% RH, non-condensing
Storage ambient humidity 10 to 90% RH, non-condensing
Vibration resistance
Compliant
with JIS B
3502 and
IEC 61131-
2
Frequency Acceleration
Half-
amplitude
Sweep
count
Under
intermittent
vibration
5 to 8.4Hz - 3.5mm
10 times
each in X,
Y and Z
directions
8.4
to150Hz
9.8m/s
2
-
Under
continuous
vibration
5 to 8.4Hz - 1.75mm
-
8.4
to 150Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
2
(15G),
3 times each in X, Y and Z directions
Operating atmosphere
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and direct sunlight (Same as storage
atmosphere)
Operating altitude
*2
2000 m (6562 ft) max.
Installation location Inside control panel
Overvoltage category
*3
II or less
Pollution degree
*4
2 or less
Cooling method Self-cooling
Grounding Grounding with a resistance of 100 or less
Point
Refer to GT16 User's Manual for details of the performance specifications of each GOT.
Note
Operation at momentary failure
If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
Make sure to power on the unit more than 5 seconds after power-off.
Item
Specifications
GT1695M-XTBA GT1685M-STBA
GT1675M-STBA
GT1675M-VTBA
GT1675-VNBA
GT1672-VNBA
GT1665M-STBA
GT1665M-VTBA
GT1662-VNBA
Input power supply voltage 100 to 240VAC (+10%, -15%)
Input frequency 50/60Hz 5%
Input max. apparent power
150VA
(maximum load)
110VA
(maximum load)
100VA
(maximum load)
Power consumption 64W or less 46W or less 39W or less
At backlight off 38W or less 32W or less 30W or less
Inrush current 28A or less (4ms) (maximum load)
3.2.2 For GOTs powered from the 24VDC power
supply
3.3 External Dimensions
Item
Specifications
GT1695M-XTBA GT1685M-STBA
GT1675M-STBA
GT1675M-VTBA
GT1675-VNBA
GT1672-VNBA
GT1665M-STBA
GT1665M-VTBA
GT1662-VNBA
Allowable momentary power
failure time
20 ms or less (100VAC or more)
Noise immunity
1,500Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60Hz
noise frequency)
Dielectric withstand voltage 1500VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a
500V DC insulation resistance tester
Applicable wire size 0.75 to 2[mm
2
]
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5 to 0.8[N•m]
Item
Specifications
GT1695M-
XTBD
GT1685M-
STBD
GT1675M-STBD
GT1675M-VTBD
GT1675-VNBD
GT1672-VNBD
GT1665M-STBD
GT1665M-VTBD
GT1662-VNBD
GT1655-VTBD
Input power supply
voltage
DC24V (+25%, -20%)
Power
consumption
60W or less 40W or less 38W or less 16W or less
At backlight off 30W or less 26W or less 27W or less 14W or less
Inrush current
12A or less
(75ms)
(maximum
load)
12A or less (55ms) (maximum
load)
67A or less
(1ms)
(maximum
load)
Allowable
momentary power
failure time
10 ms or less
Noise immunity
500Vp-p noise voltage, 1 s noise width (when measuring with a
noise simulator under 25 to 60Hz noise frequency)
Dielectric withstand
voltage
500VDC for 1 minute across power terminals and earth
Insulation
resistance
10M or more across power terminals and earth by a 500V DC
insulation resistance tester
Applicable wire size 0.75 to 2[mm
2
]
Applicable
solderless terminal
Solderess terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-
N3A
Applicable
tightening torque
(Terminal block
terminal screw)
0.5 to 0.8[N•m]
Unit:mm (inch)
397(15.6)
320(12.6)
296(11.7)
320(12.6)
6(0.24)
61(2.40)
10 382(15.0) 10
281(11.1)
(0.39) (0.39)
GT1695
10(0.39)
10(0.39)
Unit: mm (inch)
316(12.44)
240(10.35)
242(9.53)
240(9.84)
301(11.85)
52(2.05)
56(2.20)
227(8.94)
10(0.39)
GT1685
10(0.39)
6(0.24)
303 (11.93)
252 (9.92)
10(0.39)
199 (7.83)
214 (8.43)
10(0.39)
56 (2.20)
49
(1.93)
288 (11.34)
222 (8.74)
Unit: mm (inch)
GT1675,GT1672
6(0.24)
190 (7.48)
10(0.39)175 (6.89)
226 (8.90)
52
(2.05)
175.5 (6.91)
175.5 (6.91)
241 (9.49)
56 (2.20)
10(0.39)
6(0.24)
Unit: mm (inch)
GT1665,GT1662
135(5.31)
10(0.39)10(0.39)
120(4.72)
152(5.98)
6
(0.24)
116(4.57)
167(6.57)
60(2.36)
GT1655
116(4.57)