Honeywell ADEMCO 6152RF Installation And Setup Manual

Download Installation and setup manual of Honeywell ADEMCO 6152RF Keypad, Transceiver for Free or View it Online on All-Guides.com.

Brand: Honeywell

Category: Keypad , Transceiver

Type: Installation and setup manual for Honeywell ADEMCO 6152RF

Pages: 8

Download Honeywell ADEMCO 6152RF Installation and setup manual

Honeywell ADEMCO 6152RF Installation and setup manual - Page 1
1
Honeywell ADEMCO 6152RF Installation and setup manual - Page 2
2
Honeywell ADEMCO 6152RF Installation and setup manual - Page 3
3
Honeywell ADEMCO 6152RF Installation and setup manual - Page 4
4
Honeywell ADEMCO 6152RF Installation and setup manual - Page 5
5
Honeywell ADEMCO 6152RF Installation and setup manual - Page 6
6
Honeywell ADEMCO 6152RF Installation and setup manual - Page 7
7
Honeywell ADEMCO 6152RF Installation and setup manual - Page 8
8
ADEMCO 6152RF Keypad / Transceiver – Installation and Setup Guide
Fixed Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates normally-open
relay output with the functions of a 16 zone RF Receiver and a 5800 Transmitter module.
= READY to Arm
= NOT READY to Arm
= System ARMED
= System NOT ARMED
Programmable Function Keys
Arming Keys
6152RF: Fixed Word Display
2-Digit Zone Identifier
The ‘21’ digits are used for specific
trouble indications. Refer to the
control panel instructions for details.
ALARM
FIRE
AWAY
BYPASS
STAY
CHECK
INSTANT CANCELED
NO NIGHT AC
NOT READY
CHIME BAT
TESTPHONE
6152RF-KEYPAD-LBLD-07-19-13_1
Sounder
Wall
Surface
2
1
SEE Detail
A
Optional Front Cover Securing Screw
(Required in European Installations)
Install Four (4)
Mounting Screws
Control Panel
1. OPEN
Keypad
Front
Cover
2. WIRE
3. MOUNT
• Connect only one wire per terminal.
• For Daisy-Chain Configurations, use
wire splicing so only one wire is
connected to each terminal.
Mount on drywall, or in a single
or double-gang electrical box.
AUX
RELAY OUTPUT
CONNECTIONS
[ ] GROUND
[Y] DATA IN
[+] +12VDC IN
[G] DATA OUT
Ye ll ow
Black
Red
Green
CONTROL PANEL
TERMINAL STRIP
16-24 AWG Only
KEYPAD
NO
NC
C
DATA
IN
DATA
OUT
AUX
Detail
A
G
Y
To activate Function keys,
press and hold key for at
least 2 seconds; key pairs
are activated immediately.
Table 1 – Programmable
Function Keys
A or
and
B or and
C or and
D
Note: See the control’s instructions for
details on programming the Function
keys for panic alarms or other special
functions (i.e., macros).
Programmable to support the
following :
- Bi-directional 5828/5828V
wireless keypads and wireless
keys (e.g., 5804BDV, 5834-4,
etc.)
- Up to eight button-type wireless
keys locally (programmed
directly into the keypad),
without occupying control panel
zones
- Up to 16 5800 series wireless
zones programmed into any
supported control panel
- Wireless keys with high security
mode enabled
Table 2 – Settings Ke
y
Settings Ke
y
Result
Press for 2 Seconds
Enters Display Test Mode
Press for 2 Seconds
and during the Display Test,
press and hold
and
for 3 Seconds
Reboots the Keypad (the
keypad beeps and the ARM
and READY LEDs flash for
several seconds)