Whirlpool WED9600T Install Manual

Download Dimensions and installation information of Whirlpool WED9600T Dryer for Free or View it Online on All-Guides.com.

Whirlpool WED9600T Dimensions and installation information - Page 1
1
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
EXHAUST VENTING
WED9600T
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10136968
09-12-07
38"
(96.52 cm
)
*32-9/16"
(82.65 cm)
27"
(68.6 cm)
52-9/16"
(133.16 cm)
RECESSED AREA AND CLOSET INSTALLATION
A
B
14" max.*
(35.6 cm)
18" min.*
(45.72 cm)
1"*
5"**
(12.7 cm)
32-9/16"
(82.65 cm)
48 in.
2*
(310 cm
2
)
24 in.
2*
(155 cm
2
)
3"*
(7.6 cm)
3"*
(7.6 cm)
(2.5 cm)
BA
1"
(2.5 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
5"**
(12.7 cm)
27"
(68.6 cm)
32-9/16
"
(82.65 cm)
18" min.*
(45.72 cm)
14" max.*
(35.6 cm)
7"* (17.8 cm)
9"*
(22.9 cm
)
7"* (17.8 cm)
5"**
(12.7 cm)
32-9/16
"
(82.65 cm) (68.6 cm)
1"*
(2.5 cm)
1" 1"
(2.5 cm)
(2.5 cm)
27"
For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
are acceptable.
0"
(0 cm)
1"*
(2.5 cm)
1"*
(2.5 cm)
38" min.
(96.52 cm)
27"
(68.6 cm)
NOTE:
Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Number of
90° turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
A . Louvered hood style
B . Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
A
B
4"
(10.2 cm)
2-1/2"
(6.4 cm)
Dimensions shown are for minimum spacing.
Recommended hood styles
Dryer only
Dryer on pedestal
Angled hood style is
acceptable.
Select the route that will provide the straightest and most direct path outdoors. Plan the
installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Electrical: This dryer requires a 3 or 4 wire,
single phase, 120/240 volt, 60 Hz., AC only
electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating
plate) on a separate 30-amp circuit, fused on both
sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual
branch circuit. Do not have a fuse in the neutral or
grounding circuit.
Exhaust venting: Exhaust your dryer to the
outside. Four inch (10.2 cm) diameter vent is
required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vent.
Exhaust hood must be at least 12" (30.5 cm) from
the ground or any object that may be in the path of
the exhaust.
Water: The dryer must be connected to the cold
water faucet using new inlet hoses. Do not use old
hoses. Do not over tighten. Damage to the coupling
can result.
Recommended installation
spacing for cabinet installation
For cabinet installation, with a door,
the minimum ventilation openings
in the top are required.
Duet
®
Steam Electronic Electric Dryer
* Most installations require a minimum
5” (12.7 cm) clearance behind the
dryer for the exhaust vent with elbow.
See Installation Instructions, “Venting
Requirements.
®
*Required spacing
Undercounter installation - Dryer only
*Required spacing
**For side or bottom venting, 2" (5.1 cm)
spacing is allowed.
A. Side view - closet or confined area
B. Closet door with vents
A. Recessed area
B. Side view - closet or confined area
*Required spacing
**For side or bottom venting, 2" (5.1 cm)
spacing is allowed.
*Required spacing
**For side or bottom venting, 2" (5.1 cm) spacing is allowed.