Tornado Windshear Downdraft 98784 Operation & Maintenance Manual

Download Operation & maintenance manual of Tornado Windshear Downdraft 98784 Dryer, Fan for Free or View it Online on All-Guides.com.

Tornado Windshear Downdraft 98784 Operation & maintenance manual - Page 1
1
Tornado Windshear Downdraft 98784 Operation & maintenance manual - Page 2
2
TORNADO INDUSTRIES
7401 W. LAWRENCE AVENUE
CHICAGO, IL 60706
(
708) 867-5100 FAX (708) 867-6968
www.tornadovac.com
Operations & Maintenance Manual
For Commercial Use Only
Model Windshear
TM
Downdraft
MODEL NO.
98784 (115v) & 98785 (230v)
Form No. L 9701
©2007 Tacony Inc. All rights reserved.
Air
Movement!
OPERATING INSTRUCTIONS
MAINTENANCE/TROUBLE SHOOTING
1
.
P
lug in to a standard outlet with the correct voltage and amperage for the unit.
2. Place the dryer in the desired operating position.
3. Set the switch at the desired speed: low or high.
4. Check for proper operation before leaving the unit unattended.
D
o not move or carry the dryer when it is running.
5 AMP Resettable Circuit Breaker
The Downdraft™ Fan features a 5 amp circuit breaker that will “trip” if more than 5
a
mps of electrical current is drawn through the cord.
Operating Positions
The Downdraft™ Fan is designed to operate in multiple positions for any type
of drying.
1.
Face Down Set the Downdraft™ Fan on the four caster wheels to direct air
straight down. Turn each caster to a 45° angle to the housing for best airflow.
2.
Tilt Back Tilt the Downdraft™ Fan backward on the four curved molded
legs at an angle to direct air for elevated drying.
3.
Upright Set the Downdraft™ Fan square with the handle on the top to
direct air across a room.
4.
Tilt Forward Tilt the Downdraft™ Fan forward on the “standing legs at an
angle to direct airflow along the flow in front of the dryer.
5.
Stack for Storage the Downdraft™ Fan interlock and stack for easy
storage and transport.
Periodic Maintenance
1. Check power cord for any breaks, seperations or cuts.
2. Make sure the ground pin or grounding prong is intact or
the machine will be unsafe to operate.
T
r
ouble Shooting
(if the dryer will not run)
1. Check electrical cord; is it firmly seated in wall outlet
2. Check if dryer circuit breaker is tripped, reset if necessary.
3. Check to see if building circuit breaker is tripped. If circuit
is overloaded, move cord to a different outlet.
4. If using an extension cord, make sure it is in good
condition, proper gauge and firmly connected.