Maytag ALD510D Service Manual

Download Service manual of Maytag ALD510 Microwave Oven for Free or View it Online on All-Guides.com. This version of Maytag ALD510 Manual compatible with such list of devices, as: ALD510D, P1331008M, P1331010M, UALD510, UALD510D

Maytag ALD510 Service manual - Page 1
1
Maytag ALD510 Service manual - Page 2
2
Maytag ALD510 Service manual - Page 3
3
Maytag ALD510 Service manual - Page 4
4
Maytag ALD510 Service manual - Page 5
5
Maytag ALD510 Service manual - Page 6
6
Maytag ALD510 Service manual - Page 7
7
Maytag ALD510 Service manual - Page 8
8
Maytag ALD510 Service manual - Page 9
9
Maytag ALD510 Service manual - Page 10
10
Maytag ALD510 Service manual - Page 11
11
Maytag ALD510 Service manual - Page 12
12
Maytag ALD510 Service manual - Page 13
13
Maytag ALD510 Service manual - Page 14
14
Maytag ALD510 Service manual - Page 15
15
Maytag ALD510 Service manual - Page 16
16
Maytag ALD510 Service manual - Page 17
17
Maytag ALD510 Service manual - Page 18
18
Maytag ALD510 Service manual - Page 19
19
Maytag ALD510 Service manual - Page 20
20
Maytag ALD510 Service manual - Page 21
21
Maytag ALD510 Service manual - Page 22
22
Maytag ALD510 Service manual - Page 23
23
Maytag ALD510 Service manual - Page 24
24
Maytag ALD510 Service manual - Page 25
25
Maytag ALD510 Service manual - Page 26
26
Maytag ALD510 Service manual - Page 27
27
Maytag ALD510 Service manual - Page 28
28
Maytag ALD510 Service manual - Page 29
29
Maytag ALD510 Service manual - Page 30
30
Maytag ALD510 Service manual - Page 31
31
Maytag ALD510 Service manual - Page 32
32
Maytag ALD510 Service manual - Page 33
33
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.
WARNING
!
26 16026969 ©2006 Maytag Services
Adjusting Interlocks
The interlock monitor, primary, and secondary switches
act as a final safety switch, protecting the operator from
microwave energy. After adjusting the interlock switch
assembly, verify wires are correctly connected.
For door fit and switch operation, switch bracket is
adjustable.
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Loosen switch bracket mounting screws.
3. Close oven door, move switch bracket toward rear of
oven until door gap is less than
1
/64–inch (0.5 mm).
4. Hold switch bracket securely for proper switch
operation and door fit, retighten screws.
5. Open oven door slowly, watching the switches. Verify
switches release in the following order.
Primary interlock switch
Secondary interlock switch
Interlock monitor switch
NOTE: Adjust the switch bracket until all switches
operate in proper sequence.
6. Close the oven door slowly, watching the switches.
Verify switches activate in the following order.
Interlock monitor switch
Secondary interlock switch
Primary interlock switch
7. When proper switch sequence has been achieved,
tighten the switch bracket securely.
CAUTION
!
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembled,
or an adjustment of switch bracket is performed.
High Voltage Capacitor
High voltage capacitor should always be discharged by
shorting a terminal to a chassis ground. The capacitor
has a internal "shunt" resistor, but the mechanical
discharge should always be performed to avoid personal
injury.
High Voltage Capacitor Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor.
3. Remove and label wire leads from capacitor terminals.
4. Remove screw securing capacitor strap to bottom
plate.
5. Slide capacitor out of capacitor strap and remove
capacitor.
6. Replace capacitor and reverse procedure to
reassemble.
NOTE: When replacing H.V. components, route H.V.
wires at least
1
/4" from all grounded surfaces to
prevent arcing.
H.V.
Tran sformer
H.V.
Capacitor
Diode
Noise Filter
Blower
Motor
H.V.
Fuse
Diode
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect diode from high voltage capacitor and
remove screw securing diode to ground.
4. Replace diode and reverse procedure to reassemble.