NAPCO RPXP6GT Installation Instructions Manual

Download Installation instructions manual of NAPCO RPXP6GT Keypad, Security System for Free or View it Online on All-Guides.com.

Brand: NAPCO

Category: Keypad , Security System

Type: Installation instructions manual

Model: NAPCO RPXP6GT , NAPCO XP-600

Pages: 28

Download NAPCO RPXP6GT Installation instructions manual

NAPCO RPXP6GT Installation instructions manual - Page 1
1
NAPCO RPXP6GT Installation instructions manual - Page 2
2
NAPCO RPXP6GT Installation instructions manual - Page 3
3
NAPCO RPXP6GT Installation instructions manual - Page 4
4
NAPCO RPXP6GT Installation instructions manual - Page 5
5
NAPCO RPXP6GT Installation instructions manual - Page 6
6
NAPCO RPXP6GT Installation instructions manual - Page 7
7
NAPCO RPXP6GT Installation instructions manual - Page 8
8
NAPCO RPXP6GT Installation instructions manual - Page 9
9
NAPCO RPXP6GT Installation instructions manual - Page 10
10
NAPCO RPXP6GT Installation instructions manual - Page 11
11
NAPCO RPXP6GT Installation instructions manual - Page 12
12
NAPCO RPXP6GT Installation instructions manual - Page 13
13
NAPCO RPXP6GT Installation instructions manual - Page 14
14
NAPCO RPXP6GT Installation instructions manual - Page 15
15
NAPCO RPXP6GT Installation instructions manual - Page 16
16
NAPCO RPXP6GT Installation instructions manual - Page 17
17
NAPCO RPXP6GT Installation instructions manual - Page 18
18
NAPCO RPXP6GT Installation instructions manual - Page 19
19
NAPCO RPXP6GT Installation instructions manual - Page 20
20
NAPCO RPXP6GT Installation instructions manual - Page 21
21
NAPCO RPXP6GT Installation instructions manual - Page 22
22
NAPCO RPXP6GT Installation instructions manual - Page 23
23
NAPCO RPXP6GT Installation instructions manual - Page 24
24
NAPCO RPXP6GT Installation instructions manual - Page 25
25
NAPCO RPXP6GT Installation instructions manual - Page 26
26
NAPCO RPXP6GT Installation instructions manual - Page 27
27
NAPCO RPXP6GT Installation instructions manual - Page 28
28
21
8 Interior
Program an 8 in the AUX 1 and/or AUX 2
option to Bypass Exit/Entry Follower Zones
or Home/Away with Delay Zones when the
M
or
N
buttons on the Keyfob are
pressed (only if the system is programmed
exclusively for Home/Away with Delay
Zones).
[85] - [88] Wireless Smoke Detectors
Enter the RF ID# of the smoke detector.
A wireless smoke detector sends a
supervisory transmission about once every
hour. If the receiver does not receive a
signal from a transmitter in the time
programmed in Wireless Smoke
Supervisory Timer, a system trouble ‘RF
Smoke Supervisory Failure' will be indicated
on the keypad.
Program Wireless Smoke Supervisory Timer
[17] to change the time from the default time
of 8 hours. Refer to Household Fire [96-3].
Note:
Mark Smoke Detectors (Smoke 1
through Smoke 4) in order to identify them in
the event of a supervisory or battery failure.
If Household Fire [96-4] is selected,
Wireless Smoke Supervisory Time is fixed
at 4 hours.
Downloading
[90]Callback Telephone Number
Program the phone number of the
downloading computer to be dialed by the
panel during a high security download.
[91]Ring Count
Program the number of rings before the
panel will pickup. Ring Method [92-1]
(Downloading Features) must also be
selected.
[92]Downloading Features
(1) Ring Method
- Enable the ring method
of downloading. The panel will pick-up on
the number of rings programmed in Ring
Count [91].
(2) Answering Machine Override
- Using
the downloading computer, call the panel.
When the operator has determined that the
panel has received 1-2 rings, pressing the
u
key will cause the downloading
computer to immediately re-dial the panel.
The panel will pick-up on the first ring.
(3) Command 6 Download
- Select to
enable the
A
6
method of downloading
(pg. 5).
(4) Signal Strength Test Mode
- Program
to initiate a 2 hour test period. The signal
strength information for all supervisory
signals received over a two hour period will
be saved to the LOG.
[93]Auto Download ID Number
Enter the Number that is used by PCPreset
when downloading using Site Initiated Auto
Downloading (
A
6
).
The requirements for Site Initiated Auto
Downloading are as follows:
1. Download Computer running PCPreset.
2. Program the telephone number of the
Download Computer in location [90]
Callback Telephone Number.
3. Program location [93] with the number
of the PCPreset account that is to be
downloaded.
PCPreset
1. Create the XP-600 account to be
downloaded using PCD3000
Quickloader Software.
2. Create a List using PCPreset.
3. Select the account by pressing
tt
.
Select the desired account from the list
of PCD3000 accounts available. (The
location in the list is the Auto Download
ID Number [93])
4. Tag the list by entering
aD
(
download)
5. Enter Standby Mode by entering
o
.