Maytag MMV5156AAS Installation Instructions Manual

Download Installation instructions manual of Maytag MMV5156AAB Microwave Oven for Free or View it Online on All-Guides.com. This version of Maytag MMV5156AAB Manual compatible with such list of devices, as: MMV5156AAB, MMV5156AAQ, MMV5156AAS, MMV5156AAW

Maytag MMV5156AAB Installation instructions manual - Page 1
1
Maytag MMV5156AAB Installation instructions manual - Page 2
2
Maytag MMV5156AAB Installation instructions manual - Page 3
3
Maytag MMV5156AAB Installation instructions manual - Page 4
4
Maytag MMV5156AAB Installation instructions manual - Page 5
5
Maytag MMV5156AAB Installation instructions manual - Page 6
6
Maytag MMV5156AAB Installation instructions manual - Page 7
7
Maytag MMV5156AAB Installation instructions manual - Page 8
8
Maytag MMV5156AAB Installation instructions manual - Page 9
9
Maytag MMV5156AAB Installation instructions manual - Page 10
10
Maytag MMV5156AAB Installation instructions manual - Page 11
11
Maytag MMV5156AAB Installation instructions manual - Page 12
12
Maytag MMV5156AAB Installation instructions manual - Page 13
13
Maytag MMV5156AAB Installation instructions manual - Page 14
14
Maytag MMV5156AAB Installation instructions manual - Page 15
15
Maytag MMV5156AAB Installation instructions manual - Page 16
16
Maytag MMV5156AAB Installation instructions manual - Page 17
17
Maytag MMV5156AAB Installation instructions manual - Page 18
18
Maytag MMV5156AAB Installation instructions manual - Page 19
19
STEP 2: Prepare The Venting System
Standard Fittings
NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension
duct installed between the damper assembly and the adapter to prevent the exhaust damper's sticking.
Duct Length
The total length of the duct system, including straight duct, elbows, transitions, and wall or roof caps must not
exceed the equivalent of 140 feet.
For best performance, do not use more than three 90 degree elbows, and keep length as short as possible.
Below are the standard fittings and their equivalent length in feet.
3 1/4"x10"
to 6"=5ft.
3 1/4"x10" roof
cap=24ft.
3
3 1t4"x10" 90 °
elbow=25tt.
90" elbow
=10ft.
5
3 1/4"x10"
walt cap
=40ft.
6
45" elbow
:5ft.
7
3 1/4"x10"
flat elbow
=10ft.
Figure 9
To calculate the equivalent length of each duct piece used, see the examples below.
For 3 1/4"x10" SYSTEMS
Exam
1-31/4" x10" 90° elbow = 25ft.
1-Wall Cap = 40 ft.
8 feet straight duct = 8 ft.
TOTAL LENGTH = 73 ft.
_les
For 6" ROUND SYSTEMS
90" elbows _ 6ft. _ wall cap
1-transition = 5 ft.
2-90 ° elbows = 20 ft.
1-Wall Cap = 40 ft.
8 feet straight = 8 ft.
TOTAL LENGTH = 73 ft.
10