Maytag MER6770AAW Service Manual

Download Service manual of Maytag GEMINI Cooktop, Ranges for Free or View it Online on All-Guides.com. This version of Maytag GEMINI Manual compatible with such list of devices, as: GEMINI, MER6770AAB, MER6770AAC, MER6770AAW

Maytag GEMINI Service manual - Page 1
1
Maytag GEMINI Service manual - Page 2
2
Maytag GEMINI Service manual - Page 3
3
Maytag GEMINI Service manual - Page 4
4
Maytag GEMINI Service manual - Page 5
5
Maytag GEMINI Service manual - Page 6
6
Maytag GEMINI Service manual - Page 7
7
Maytag GEMINI Service manual - Page 8
8
Maytag GEMINI Service manual - Page 9
9
Maytag GEMINI Service manual - Page 10
10
Maytag GEMINI Service manual - Page 11
11
Maytag GEMINI Service manual - Page 12
12
Maytag GEMINI Service manual - Page 13
13
Maytag GEMINI Service manual - Page 14
14
Maytag GEMINI Service manual - Page 15
15
Maytag GEMINI Service manual - Page 16
16
Maytag GEMINI Service manual - Page 17
17
Maytag GEMINI Service manual - Page 18
18
Maytag GEMINI Service manual - Page 19
19
Maytag GEMINI Service manual - Page 20
20
Maytag GEMINI Service manual - Page 21
21
Maytag GEMINI Service manual - Page 22
22
Maytag GEMINI Service manual - Page 23
23
Maytag GEMINI Service manual - Page 24
24
Maytag GEMINI Service manual - Page 25
25
Maytag GEMINI Service manual - Page 26
26
Maytag GEMINI Service manual - Page 27
27
Maytag GEMINI Service manual - Page 28
28
Maytag GEMINI Service manual - Page 29
29
Maytag GEMINI Service manual - Page 30
30
Maytag GEMINI Service manual - Page 31
31
Maytag GEMINI Service manual - Page 32
32
Maytag GEMINI Service manual - Page 33
33
Maytag GEMINI Service manual - Page 34
34
Maytag GEMINI Service manual - Page 35
35
Maytag GEMINI Service manual - Page 36
36
Maytag GEMINI Service manual - Page 37
37
Maytag GEMINI Service manual - Page 38
38
Maytag GEMINI Service manual - Page 39
39
Maytag GEMINI Service manual - Page 40
40
Maytag GEMINI Service manual - Page 41
41
Maytag GEMINI Service manual - Page 42
42
Maytag GEMINI Service manual - Page 43
43
Maytag GEMINI Service manual - Page 44
44
Maytag GEMINI Service manual - Page 45
45
Maytag GEMINI Service manual - Page 46
46
Maytag GEMINI Service manual - Page 47
47
Maytag GEMINI Service manual - Page 48
48
Maytag GEMINI Service manual - Page 49
49
Maytag GEMINI Service manual - Page 50
50
16010107 Section 5. Troubleshooting
©2000 Maytag Appliances Sales Company
RELAY BOARD
Relay Board: The relay board will be equipped to operate the following outputs. Some shown can
be optional. The Double Line Break (DLB) is located remotely, off board from the main control.
Engineering Mode: Used to view the actual
oven temperature for both ovens at all times,
even when an oven function is active. This
mode will also display the current fault code for
5 seconds in the time digits. Enter the
engineering mode by pressing the Bake Key of
either oven, enter a bake temperature of 100ºF,
then hold Bake down for 3 seconds within 30
seconds of initial Bake press. The mode can
be exited by pressing Cancel.
Oven Light: Oven light key toggles the oven
light on and off. Oven light is deactivated
during a clean cycle.
Dual Line Break Relay: Canadian Models
Only. Relay wil be a 17 amp, 240 VAC
minimum contact rating. There will also be a
5.6 Ohm resistor and a connection to the
normally open contact on Canadian models to
allow for "Hi-Pot" testing at the factory.
50/60 Hertz Option: Control automatically
senses cycle rate of supply line.
Demo Mode: The control can be placed in a
sales demo mode by pressing Bake and Cancel
keys for 3 seconds. The demo mode can be
exited by pressing any key. This mode will
activate the display as if the unit is operating
without energizing the heating elements.
RELAY OUTPUTS
VOLTAGE
(Volts AC)
CURRENT
(Amps)
RESISTANCE
VALUE
Lower Broil - 3600 Watts 240 15 16 ohms
Lower Bake - 2585 Watts 240 10.8 21 ohms
Convect* 120 0.28 430 ohms
Upper Broil - 2200 Watts 240 9.17 25 ohms
Upper Bake - 1800 Watts 240 9.17 25 ohms
Upper Oven Light 12 0.8 15 ohms
Lower Oven Light 12 0.8 15 ohms
Upper Door Lock 120 0.03 4000 ohms
Lower Door Lock 120 0.03 4000 ohms
Upper Double Line Break 240 17
Lower Double Line Break 240 17
SURFACE ELEMENT VALUES VOLTS WATTS RESISTANCE (ohms)
Left Front/Right Rear 240 1200 46 ohms
Left Rear 240 2200 25 ohms
Right Front/Dual 240 750 inner/1450 outer 74 inner/38 outer
5-3