fuelg
Syntax fuelg -T system:mm[x] <domain> <-qm (off | on)>
Release Information Command supported by Junos OS Release 9.1 and later.
Description (JCS management module CLI) Display or configure power domain information for power
supplies on the JCS1200 platform.
Options -T system:mm[x]—Specify the JCS management module as the target of the command.
Replace x with a value of 1 or 2.
domain—(Optional) Display information for a specific power domain. Replace domain
with pd1 (power domain 1) or pd2 (power domain 2). By default, power domain information
is displayed for both power domains.
The JCS1200 platform has two power domains. Power domain 1 supports all JCS modules
and slots (bays) 1 through 6. Power domain 1 uses power supply modules 1 and 2. Power
domain 2 supports slots 7 through 12 and uses power supply modules 3 and 4.
-qm (on | off)—(Optional) Specify a thermal event response (quiet mode):
• off—Fans will increase speed to provide additional cooling.
• on—Fans will remain at fixed speed. Power is throttled (for components that support
power throttling) to reduce power consumption and heat.
Required Privilege
Level
supervisor (configure)
operator (display)
Related
Documentation
Displaying Power Domain Information on page 203•
List of Sample Output fuelg (Display) on page 215
fuelg (Configure) on page 215
Output Fields Table 25 on page 214 lists the output fields for the fuelg command. Output fields are listed
in the approximate order in which they appear.
Table 25: fuelg Output Fields
Field DescriptionField Name
Status information for the power domain (power domain 1 or power
domain 2).
Domain Number
Bay (slot) number and power value (in watts) for the power supply.Bay x
Total amount of power (in watts) allocated to the domain.Power Budget
Amount of power (in watts) held in reserve.Reserved Power
Copyright © 2010, Juniper Networks, Inc.214