Honeywell ADEMCO 6150RF Installation And Setup Manual

Download Installation and setup manual of Honeywell ADEMCO 6150RF Keypad, Security System for Free or View it Online on All-Guides.com.

Brand: Honeywell

Category: Keypad , Security System , Transceiver

Type: Installation and setup manual for Honeywell ADEMCO 6150RF

Pages: 8 (0.17 Mb)

Download Honeywell ADEMCO 6150RF Installation and setup manual

Honeywell ADEMCO 6150RF Installation and setup manual - Page 1
1
Honeywell ADEMCO 6150RF Installation and setup manual - Page 2
2
Honeywell ADEMCO 6150RF Installation and setup manual - Page 3
3
Honeywell ADEMCO 6150RF Installation and setup manual - Page 4
4
Honeywell ADEMCO 6150RF Installation and setup manual - Page 5
5
Honeywell ADEMCO 6150RF Installation and setup manual - Page 6
6
Honeywell ADEMCO 6150RF Installation and setup manual - Page 7
7
Honeywell ADEMCO 6150RF Installation and setup manual - Page 8
8
- 3 -
An example of an installation using two 6150RF
Keypad/Transceivers with 2-Way Wireless Devices (e.g.,
5828V) on Two Partitions is shown below:
Settings 6150RF #1 6150RF #2
Keypad: Must be assigned to
Partition 1 in the
control panel
Must be assigned to
Partition 2 in the
control panel
House ID: Match Partition 1
House ID in the
control panel and
House ID in Wireless
Device
Match House ID in
Wireless Device
House ID
Source:
System Local
Receiver
Enable:
On Off
Transmitter
Enable:
On On
PROGRAMMING THE 6150RF
The 6150RF is shipped with pre-programmed default
values. Later in these instructions are diagrams showing
the wireless keys' loops and their default functions.
Regardless of which wireless key you use (even if it is one
not shown), loops 1-4 are defaulted for all eight devices as
shown. These values may be changed to suit the
installation.
Entering Program Mode
Press the [1] and [3] keys simultaneously for a few seconds,
within 30 seconds after applying power. The keypad beeps
three (3) times, and two dashes and two zeroes flash
alternately in the upper left-hand corner of the display. If
any other numbers or letters flash in the display, press the
[] key.
Note: The keypad will not enter programming mode if the system
has been armed before the 6150RF was powered up or
down.
Pressing the [1] and [3] keys 30 seconds or more after
applying power allows you to enter the User mode. This mode
allows you to enable and disable individual local wireless keys
(useful if, e.g., a user accidentally loses a wireless key). Refer
to the User Guide for instructions.
Programming Operations
Once you have entered the Program mode, you may move to
any program address simply by entering the program
address number. The 6150RF will automatically exit the
Program mode if no keys are pressed for 90 seconds. While
in the Program mode:
Pressing the [] key stores the information displayed,
then moves you to the next prompt, and the keypad beeps
twice.
Pressing the [#] key erases the current information and
moves you back so you may enter the correct information.
Enter a program address (e.g., press [1] for Keypad
Address; [2] for Receiver Address) to set the parameters in
the 6150RF.The following chart lists the program addresses,
the keypad display, and the choices.
Program
Address
Description Display Choices Default
1 Keypad Address cA 01-31 31
2 Receiver Address rA 00-30 00
3 House ID HI 01-31 10
4 House ID Source hS 1 = System
0 = Local
1 System
5 Wireless Key Editing d- Enter Existing Device Number
6 Receiver Enable rE 1 = On 0 = Off 1 Enable
7 Transmitter Module Enable tE 1 = On 0 = Off 1 Enable
8 Wireless Key Auto Enroll d* Enter Serial Number
8 then 2 Wireless Key User Code u4 Enter 4-Digit User Code
8 then 4 Wireless Key Loop Function Ln Enter Loop Number then Function
(See Wireless Key Function Chart)
Loop 2 1 (Disarm)
Loop 3 2 (Arm Away)
Loop 4 3 (Arm Stay)
8 then 5 Wireless Key On-Board Relay
Assignment
o- Enter Loop Number then Relay
Action
Loop 1 Close for 2 Seconds
9 Restore Defaults EE 1 = Restores Defaults
Any Other Key = Does Not
Restore Defaults
0 High Security Mode En 1 = Enable; 0 = Disable 0 Disable
* The keypad will display the next number that can be enrolled (i.e., “d3”)
When operating the system in High-Security mode, non-encrypted wireless keys will not function.
CONTROL
PANEL
6150RF
#1
6150RF
#2