Figure 7-43 Connect the Turbo Fan Cable
Front of Chassis
18. Connect the power module cable to the connector on the system board.
Figure 7-44 Connect the Power Module Cable
Front of Chassis
19. Place the processor airflow guide in position. See “Installing the Processor Airflow Guide”
(page 128).
20. Install the chassis top cover. See “Removing and Replacing the Top Cover” (page 123).
21. If necessary, reinstall the chassis in the rack. See “Inserting the Server Into a Rack” (page 116).
22. Reconnect power and system cables to rear panel connectors.
23. Turn on the system.
24. Run the info cpu command at the EFI Shell prompt to verify that the processor has been
installed correctly.
Removing and Replacing the System Battery
Replace the non-rechargeable system battery by removing the top cover and accessing the system
board while the server is mounted in a rack, or after removing it from the rack.
160 Removing and Replacing Components