Hewlett-Packard Integrity cx2600 Maintenance Manual
Download Maintenance manual of HP Integrity cx2600 Server for Free or View it Online on All-Guides.com.
NOTE: Air flows through the server chassis from front to back.
Removing the Memory Airflow Guide
To remove the memory airflow guide, follow these steps:
1. Power off the server.
2. Remove the top cover. See “Removing and Replacing the Top Cover” (page 123).
3. Grasp the memory airflow guide and lift it from the server chassis.
Installing the Memory Airflow Guide
To install the memory airflow guide, follow these steps:
1. Reposition cables away from the area where you install the airflow guide.
2. Align the tab on the airflow guide with the corresponding slot on the server chassis.
3. Insert the tab into the slot and set the memory airflow guide in place above the DIMMs and
DIMM connectors.
Removing the Processor Airflow Guide
To remove the processor airflow guide, follow these steps:
1. Power off the server.
2. Remove the top cover. See “Removing and Replacing the Top Cover” (page 123).
3. Grasp the processor airflow guide and lift it from the server chassis.
Installing the Processor Airflow Guide
To install the processor airflow guide, follow these steps:
1. Align the tabs on the airflow guide with the corresponding slot on the server chassis.
2. Insert the tabs into the slots and set the processor airflow guide in place above the processors.
Removing the PCI Airflow Guide
To remove the PCI airflow guide, follow these steps:
1. Power off the server.
2. Remove the top cover. See “Removing and Replacing the Top Cover” (page 123).
3. Loosen the three captive screws that secure the PCI-X airflow guide in place. Two screws
are elevated and one is on the opposite side of the airflow guide.
4. Grasp the PCI-X airflow guide and lift and twist it from the server chassis.
Installing the PCI Airflow Guide
To install the PCI airflow guide, follow these steps:
1. Reposition cables away from the area where the airflow guide is to be installed.
2. Position the airflow guide into the opening in front of the PCI-X card cage.
3. Tighten the three captive screws to secure the airflow guide in place. Two screws are elevated
and one is on the opposite side of the airflow guide.
Removing and Replacing System Memory DIMMs
Your hp Integrity cx2600 Server comes with 4, 8, or 12 DIMMs installed. The system is minimally
configured with 1GB of memory (four 256 MB DIMMs loaded in quad 0 (slots 0A, 0B, 1A, and
1B). The system is maximally configured with 24 GB of memory (four 2 GB DIMMs loaded in
each of quads 0, 1, and 2 (quad 0 slots 0A, 0B, 1A, and 1B, quad 1 slots 2A, 2B, 3A, and 3B, and
quad 2 slots 4A, 4B, 5A, and 5B.
128 Removing and Replacing Components