SpectraLink Corporation Installation
Link WTS – Link 3000 MCU
Part Number: 72-0059-01-J.doc Page 16
backboard, along with standoffs at least 1.5” long with 1/4” inside diameter.
Power and Conduit -48V Power Source and conduit for connection, either
1/2” BX metallic or NMX conduit. Three #8 insulated rings for use with #14
AWG wire are required for each MCS300 to be installed.
25-Pair Cables RJ-21 male at MCU end, required to connect the shelves to the
cross-connect blocks.
Cross-Connect Blocks Required to connect the PBX ports and the Base
Stations to the MCU.
Quick Clip Fuse Required with an RCO400 Outdoor Base Station or when a
Base Station is located in a separate building from the Link 3000 MCU.
Recommended Quick Clip Fuse is available from Reliable Electric, Model #
RSCP-2.
Ladder SpectraLink installation crew will require a ladder to reach the Base
Station locations. Ensure that a ladder of adequate height is available for the
crew’s exclusive use upon arrival.
Operator’s Console PC
A PC must be available to perform system administration and diagnostics The PC
must conform to the following specifications:
• An IBM-compatible personal computer, 486 or above (with a 16 MHz clock or
faster)
• A hard disk with at least 2 Mbytes free space
• At least 640k bytes of RAM
• MS-DOS 3.2 (or later), or MS-Windows 95 (or above) or NT
• A 3 1/2” floppy-disk drive (high density, 1.44 Mbytes)
• One RS-232 serial port for connection to the system controller
If remote access is required, the customer must supply an external modem, 9600
baud or faster.
System Administrator
One person (or more, depending on the size of the system) must be designated as
the system administrator for the Link WTS. This person is often also the company’s
telephone system administrator. This person should know the location of the
company’s current telephone equipment, have access to the telephone room, know
the telephone system’s feature codes, and should be present for the installation. If
there is not currently a person carrying out such duties, someone must be designated
as system administrator.
The system administrator’s tasks are minimal but may take up to two hours per week
for a large system. The system administrator should have access to the location of
the SpectraLink system and be competent to perform the following functions:
• Swap system components (handsets, Base Stations)