Haier 102102429 Service Manual

Download Service manual of Haier 102102429 Refrigerator for Free or View it Online on All-Guides.com.

Brand: Haier

Category: Refrigerator

Type: Service manual for Haier 102102429

Pages: 35 (0.83 Mb)

Download Haier 102102429 Service manual

Haier 102102429 Service manual - Page 1
1
Haier 102102429 Service manual - Page 2
2
Haier 102102429 Service manual - Page 3
3
Haier 102102429 Service manual - Page 4
4
Haier 102102429 Service manual - Page 5
5
Haier 102102429 Service manual - Page 6
6
Haier 102102429 Service manual - Page 7
7
Haier 102102429 Service manual - Page 8
8
Haier 102102429 Service manual - Page 9
9
Haier 102102429 Service manual - Page 10
10
Haier 102102429 Service manual - Page 11
11
Haier 102102429 Service manual - Page 12
12
Haier 102102429 Service manual - Page 13
13
Haier 102102429 Service manual - Page 14
14
Haier 102102429 Service manual - Page 15
15
Haier 102102429 Service manual - Page 16
16
Haier 102102429 Service manual - Page 17
17
Haier 102102429 Service manual - Page 18
18
Haier 102102429 Service manual - Page 19
19
Haier 102102429 Service manual - Page 20
20
Haier 102102429 Service manual - Page 21
21
Haier 102102429 Service manual - Page 22
22
Haier 102102429 Service manual - Page 23
23
Haier 102102429 Service manual - Page 24
24
Haier 102102429 Service manual - Page 25
25
Haier 102102429 Service manual - Page 26
26
Haier 102102429 Service manual - Page 27
27
Haier 102102429 Service manual - Page 28
28
Haier 102102429 Service manual - Page 29
29
Haier 102102429 Service manual - Page 30
30
Haier 102102429 Service manual - Page 31
31
Haier 102102429 Service manual - Page 32
32
Haier 102102429 Service manual - Page 33
33
Haier 102102429 Service manual - Page 34
34
Haier 102102429 Service manual - Page 35
35
27
a) Check the input power circuit to see whether where is voltage of the
power supply, namely, the circuit which is connected to the knife switch.
This can be determined with an avometer or a test pencil. If a blown fuse is
found, ascertain and remove its cause, then replace it with a new one of
the same specifications.
b) Check the compressor accessories, including its thermal protector
and relay. In case the thermal protector is damaged, the compressor
cannot be powered on. If the relay is out of order, the motor will not run and
hum sound can be heard from it after the compressor is turned on, in that
case, shut it down immediately, otherwise, the motor windings will be
burned out in case this condition lasts longer.
c) Check the relay contacts and plugs to see if they are perfect and
work reliably. Poor contact may cause the motor not running or humming.
2) Check the circuit voltage to see whether it is normal.
Analysis of trouble
If the circuit voltage is obviously lower than its rated value, it will be
difficult to start the motor, and a hum sound can be heard from it.
Remedy
Measure the voltage with a voltmeter, if it is really too low, give
directions to the user for buying a stabilizer so as to step up the voltage,
thus normal operation can be achieved.
3) Check the thermal relay to see whether its contacts are closed.
Analysis of Trouble
The contacts of thermal relay sometimes may be open due to the
leakage of temperature sensing agent from the temperature sensor.
Remedy
Remove the relay cover to check up its contacts, if they are open, this
means that the original setting is not properly set or temperature sensing
agent has leaked out of the temperature sensor. Try to turn the adjusting
stem of this value in the direction of the lower temperature graduation, then
check the contacts to see whether they are closed. If they are still not
closed, dismantle the temperature sensing disc and then immerse it into
warm water to see whether the contacts actuate, if not, it can be
preliminarily determine that temperature sensing agent has leaked out, and
it must be replaced with a new thermostat.
4) Motor troubles and other electric faults
a) Motor windings have been burned or short-circuited between turns
Analysis of Trouble
When motor windings have been burned or short-circuited between
turns, the fuse will be blown repeatedly, and the blowout occurs particularly
at the instant when you close the knife switch.
Remedy
Check the terminals and the outer casing to see whether they are
short-circuited, and measure the resistance of each phase with an
Maintenance Service and Trouble Shooting