Haier HGRP301AAWW User Manual

Download Operation & user’s manual of Haier DIV22 Cooktop for Free or View it Online on All-Guides.com. This version of Haier DIV22 Manual compatible with such list of devices, as: HGRA241AAWW, HGRA242EAWW, HGRA302QABS, HGRP201AAWW, HGRP241AAWW

Haier DIV22 Operation & user’s manual - Page 1
1
Haier DIV22 Operation & user’s manual - Page 2
2
Haier DIV22 Operation & user’s manual - Page 3
3
Haier DIV22 Operation & user’s manual - Page 4
4
Haier DIV22 Operation & user’s manual - Page 5
5
Haier DIV22 Operation & user’s manual - Page 6
6
Haier DIV22 Operation & user’s manual - Page 7
7
Haier DIV22 Operation & user’s manual - Page 8
8
Haier DIV22 Operation & user’s manual - Page 9
9
Haier DIV22 Operation & user’s manual - Page 10
10
Haier DIV22 Operation & user’s manual - Page 11
11
Haier DIV22 Operation & user’s manual - Page 12
12
Haier DIV22 Operation & user’s manual - Page 13
13
Haier DIV22 Operation & user’s manual - Page 14
14
Haier DIV22 Operation & user’s manual - Page 15
15
Haier DIV22 Operation & user’s manual - Page 16
16
Haier DIV22 Operation & user’s manual - Page 17
17
Haier DIV22 Operation & user’s manual - Page 18
18
Haier DIV22 Operation & user’s manual - Page 19
19
Haier DIV22 Operation & user’s manual - Page 20
20
Haier DIV22 Operation & user’s manual - Page 21
21
Haier DIV22 Operation & user’s manual - Page 22
22
Haier DIV22 Operation & user’s manual - Page 23
23
Haier DIV22 Operation & user’s manual - Page 24
24
Haier DIV22 Operation & user’s manual - Page 25
25
Haier DIV22 Operation & user’s manual - Page 26
26
Haier DIV22 Operation & user’s manual - Page 27
27
Haier DIV22 Operation & user’s manual - Page 28
28
Haier DIV22 Operation & user’s manual - Page 29
29
Haier DIV22 Operation & user’s manual - Page 30
30
Haier DIV22 Operation & user’s manual - Page 31
31
Haier DIV22 Operation & user’s manual - Page 32
32
GAS CONNECTIONS (All Units), Continued
Have the dealer where you purchase your new range install it or have him recommend a
qualified installer. Installation must conforna with local codes, in the absence of local
codes, the installation must conform with the National Fuel Gas Code, ANSI Z223.1-
Latest Edition in the U.S.A. or the CANiCGA B149.1 or .2 Installation Codes in Canada.
The range should be connected to the supply line with li2-inch black iron pipe or a
certified flexible type stove connector. To prevent gas leaks, put an approved sealing
compound, which is resistant to liquefied petroleum gases, on all threaded connections.
lnq)ortant." Do not apply pressure directly to the range manifold pipe when tightening
supply connections. The manifold pipe should be held securely at the pressure regulator
to prevent twisting. Hold the pressure regulator with a wrench during the tightening of the
connection, or the manifold pipe may be twisted and split, and cause a dangerous leak.
The installation of ranges designed for manufactured (mobile) home installation must
conform with the Manufactured Construction and Safety, Title 24 CFR, Part 3280,
[formerly the Federal standard for Mobile Home Construction and Safety, Title 24, HUD
(Part 280)] in the U.S.A. or C.S.A. Standard CAN/CGA Z240.4.2 in Canada or, when such
standards are not applicable with local codes.
The installation of ranges designed for recreational vehicle installation must conform with
state or other codes or, in the absence of such codes, with the standard for recreational
vehicles. ANSI A119.2.2 1982 in the U.S.A. or CANiCGA Z240.4.2 in Canada.
The installation of appliances designed for recreational park trailers must conform with
state or other codes or, in the absence of such codes, with the standard for recreational
park trailers, ANSI A119.5.
Note." Check all piping connections in the unit for leaks. Never use an open flame to check
for gas leaks. Use a soap solution. It is not impossible for connections made at the factory
to leak, due to vibration encountered in transportation. Make certain you have checked
them all, and repair any connections that leak.
The appliance and its individual shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of I/2
psig.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig.
Electrical Connections
All electrical wiring and attachments are 60-cycle, 120 volts, 15 amp max. Your range is
grounded with a three-conductor (three-prong plug) supply cord which will ground the
range when plugged into a GROUNDED wall receptacle. If the backguard of the range
has a clock or light, connect the cord from the backguard into the special terminal block
located at the top of the main back directly under the backguard supply cord.
The appliance must be electrically grounded when installed in accordance with local
codes, or in the absence of local codes, with the National Electrical Code, ANSIiNFPA
No. 70 Latest Edition in the U.S.A. or the Canadian Electrical Code, C22.1; Part 1 in
Canada, if an external electrical source is utilized.