SMEG PVA750A Manual

Download Manual  of Smeg PVA750A Burner for Free or View it Online on All-Guides.com.

Brand: Smeg

Category: Burner

Type: Manual 

Model: Smeg PVA750A , Smeg PVA750A-1 , Smeg PVS750A

Pages: 20 (2.43 Mb)

Download Smeg PVA750A Manual 

Smeg PVA750A Manual  - Page 1
1
Smeg PVA750A Manual  - Page 2
2
Smeg PVA750A Manual  - Page 3
3
Smeg PVA750A Manual  - Page 4
4
Smeg PVA750A Manual  - Page 5
5
Smeg PVA750A Manual  - Page 6
6
Smeg PVA750A Manual  - Page 7
7
Smeg PVA750A Manual  - Page 8
8
Smeg PVA750A Manual  - Page 9
9
Smeg PVA750A Manual  - Page 10
10
Smeg PVA750A Manual  - Page 11
11
Smeg PVA750A Manual  - Page 12
12
Smeg PVA750A Manual  - Page 13
13
Smeg PVA750A Manual  - Page 14
14
Smeg PVA750A Manual  - Page 15
15
Smeg PVA750A Manual  - Page 16
16
Smeg PVA750A Manual  - Page 17
17
Smeg PVA750A Manual  - Page 18
18
Smeg PVA750A Manual  - Page 19
19
Smeg PVA750A Manual  - Page 20
20
Instructions for the Installer
10
5.1 Clearances above and around domestic appliances
Extract from AS5601
REQUIREMENTS
1. Overhead clearances – (Measurement A)
Range hoods and exhaust fans shall be installed in accordance with the
manufacturer’s instructions. However, in no case shall the clearance between
the highest part of the hob of the cooking appliance and a range hood be less
than 600 mm or, for an overhead exhaust fan, 750 mm.
Any other downward facing combustible surface less than 600 mm above the
highest part of the hob shall be protected for the full width and depth of the
cooking surface area in accordance with Clause 5.12.1.2. However, in no
case shall this clearance to any surface be less than 450 mm.
2. Side clearances – (Measurements B & C)
Where B, measured from the periphery of the nearest burner to any vertical
combustible surface, is less than 200 mm, the surface shall be protected in
accordance with Clause 5.12.1.2 to a height C of not less than 150 mm
above the hob for the full dimension (width or depth) of the cooking surface
area. Where the cooking appliance is fitted with a ‘splashback’, protection of
the rear wall is not required.
3. Additional requirements for Freestanding and Elevated Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest burner to a
horizontal combustible surface is less than 200 mm, then E shall be 10 mm
or more, or the horizontal surface shall be above the trivet. See insets above.