GE 36
1
GE 36
2
ZVC36LSS
GE Monogram
®
36" Custom Hood Insert
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Created 10/06
Custom Insert Liner
The custom canopy must be sized to fit the insert sleeve.
Construct the canopy with an opening that is:
26"W x 13-3/16"D
The opening must be constructed of 3/4" thick material to
allow the sleeve locking clips to engage.
Dimensions and Specifications (in inches)
Outside Dimensions
The Insert Sleeve
The bottom edge of the insert sleeve has a 7/8" wide flange
on the sides and a 1/2" wide flange on the front and back.
Remote Location for the Control
The control may be removed from the hood and installed
into a wall or countertop. A 30-ft length of wire is supplied to
accommodate most installations. A blanking plate covers the
opening when the controls are removed. The overall size of
the control is 4-1/4" wide and 2-1/4" deep.
1-11/16"
3-11/16"
We recommend that the cutout in granite or other hard
surfaces be made before the countertop is installed.
The Supplied Liner
A stainless steel liner is shipped with each hood insert. This
non-combustible liner protects the underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may construct a
custom non-combustible liner. Use the supplied liner as a
template. The opening must be 26"W x 13-3/16"D. 3/4" thick
material must surround the opening to allow the sleeve
locking clips to engage. The insert sleeve inside the cabinet
should be positioned 1/2" from the rear wall so that the
center of the 8" duct is 5-1/2" from the rear wall.
130674