25% load 50% load 75% load 100% load
85.5% 91.7% 92.8% 92.9%
89.0% 92.4% 92.8% 92.6%
25% load 50% load 75% load 100% load
95.5% 97.6% 98.3% 98.5%
96.6% 98.1% 98.5% 98.7%
Heat rejection in Double Conversion operating mode
@0.9 pf lagging load, nominal voltage/frequency, energy storage disconnected
25% load 50% load 75% load 100% load
29295 31270 40207 52807 BTU/hr
8.6 9.2 11.8 15.5 kW
28466 37888 53609 73623 BTU/hr
8.3 11.1 15.7 21.6 kW
Heat rejection in eBoost Operating mode
@0.9 pf lagging load, nominal voltage/frequency, energy storage disconnected
25% load 50% load 75% load 100% load
8140 8495 8962 10522 BTU/hr
2.4 2.5 2.6 3.1 kW
8106 8922 10522 12134 BTU/hr
2.4 2.6 3.1 3.6 kW
Max Cooling Air (77°F - 86°F / 25°C - 30°C) (225/300kVA)
Double Conversion Mode
eBoost Mode
UPS
Battery
UPS
Battery
(VRLA)
Relative humidity
ft (M)
4921ft
(1500Mts)
6562ft
(2000Mts)
8202ft
(2500Mts)
9843ft
(2500Mts)
ft
(M)
-5% -9% -14% -18%
Derating
System Efficiency in Double Conversion operating mode
@0.9 pf lagging load, nominal voltage/frequency, energy storage disconnected
(Note: Higher temperatures shorten battery life)
(Note: Higher temperatures reduce battery storage time)
300kVA with 5th filter
3281 / 1000 (no derating)
60 dB(A)
32°F - 104°F (0°C - 40°C)
68°F - 77°F (20°C - 25°C)
Operating temperature range
Audible noise level (at 5 ft./1.52Mts)
67 dB(A)
300kVA with 5th filter
300kVA with 5th filter
225kVA with 5th filter
2661 / 3709 CFM
Digital Energy
SG Series Uninterruptable Power Supply
225-300kVA UL listed with eBoost
TM
Storage time is 6 months at 77°F (25°C).
Topology
System Efficiency in eBoost Operating mode
@0.9 pf lagging load, nominal voltage/frequency, energy storage disconnected
225kVA with 5th filter
General Data
Nominal output power at pf = 0.9 lag.
g
Technical Data Sheet - 225-300kVA UL Listed
300kVA with 5th filter
225kVA with 5th filter
True On-line double conversion
300kVA (270kW) / 225kVA (202.5kW)
0-95%, non-condensing
Maximum Altitude
225kVA with 5th filter
32°F - 104°F (0°C - 40°C)
5°F - 122°F (-15°C to +50°C)
Storage temperature range
Energy
Digital Energy
g
imagination at work
GEA-D2041 (225 300kVA TDS), Page: 1