Fluke 199B Service Manual

Download Service manual of Fluke 192B Accessory, Measuring Instruments for Free or View it Online on All-Guides.com. This version of Fluke 192B Manual compatible with such list of devices, as: 192C, 196B, 196C, 199B, 199C

Fluke 192B Service manual - Page 1
1
Fluke 192B Service manual - Page 2
2
Fluke 192B Service manual - Page 3
3
Fluke 192B Service manual - Page 4
4
Fluke 192B Service manual - Page 5
5
Fluke 192B Service manual - Page 6
6
Fluke 192B Service manual - Page 7
7
Fluke 192B Service manual - Page 8
8
Fluke 192B Service manual - Page 9
9
Fluke 192B Service manual - Page 10
10
Fluke 192B Service manual - Page 11
11
Fluke 192B Service manual - Page 12
12
Fluke 192B Service manual - Page 13
13
Fluke 192B Service manual - Page 14
14
Fluke 192B Service manual - Page 15
15
Fluke 192B Service manual - Page 16
16
Fluke 192B Service manual - Page 17
17
Fluke 192B Service manual - Page 18
18
Fluke 192B Service manual - Page 19
19
Fluke 192B Service manual - Page 20
20
Fluke 192B Service manual - Page 21
21
Fluke 192B Service manual - Page 22
22
Fluke 192B Service manual - Page 23
23
Fluke 192B Service manual - Page 24
24
Fluke 192B Service manual - Page 25
25
Fluke 192B Service manual - Page 26
26
Fluke 192B Service manual - Page 27
27
Fluke 192B Service manual - Page 28
28
Fluke 192B Service manual - Page 29
29
Fluke 192B Service manual - Page 30
30
Fluke 192B Service manual - Page 31
31
Fluke 192B Service manual - Page 32
32
Fluke 192B Service manual - Page 33
33
Fluke 192B Service manual - Page 34
34
Fluke 192B Service manual - Page 35
35
Fluke 192B Service manual - Page 36
36
Fluke 192B Service manual - Page 37
37
Fluke 192B Service manual - Page 38
38
Fluke 192B Service manual - Page 39
39
Fluke 192B Service manual - Page 40
40
Fluke 192B Service manual - Page 41
41
Fluke 192B Service manual - Page 42
42
Fluke 192B Service manual - Page 43
43
Fluke 192B Service manual - Page 44
44
Fluke 192B Service manual - Page 45
45
Fluke 192B Service manual - Page 46
46
Fluke 192B Service manual - Page 47
47
Fluke 192B Service manual - Page 48
48
Fluke 192B Service manual - Page 49
49
Fluke 192B Service manual - Page 50
50
Fluke 192B Service manual - Page 51
51
Fluke 192B Service manual - Page 52
52
Fluke 192B Service manual - Page 53
53
Fluke 192B Service manual - Page 54
54
Fluke 192B Service manual - Page 55
55
Fluke 192B Service manual - Page 56
56
Fluke 192B Service manual - Page 57
57
Fluke 192B Service manual - Page 58
58
Fluke 192B Service manual - Page 59
59
Fluke 192B Service manual - Page 60
60
Fluke 192B Service manual - Page 61
61
Fluke 192B Service manual - Page 62
62
Fluke 192B Service manual - Page 63
63
Fluke 192B Service manual - Page 64
64
Fluke 192B Service manual - Page 65
65
Fluke 192B Service manual - Page 66
66
Fluke 192B Service manual - Page 67
67
Fluke 192B Service manual - Page 68
68
Fluke 192B Service manual - Page 69
69
Fluke 192B Service manual - Page 70
70
Fluke 192B Service manual - Page 71
71
Fluke 192B Service manual - Page 72
72
Fluke 192B Service manual - Page 73
73
Fluke 192B Service manual - Page 74
74
Fluke 192B Service manual - Page 75
75
Fluke 192B Service manual - Page 76
76
Fluke 192B Service manual - Page 77
77
Fluke 192B Service manual - Page 78
78
Fluke 192B Service manual - Page 79
79
Fluke 192B Service manual - Page 80
80
Fluke 192B Service manual - Page 81
81
Fluke 192B Service manual - Page 82
82
Fluke 192B Service manual - Page 83
83
Fluke 192B Service manual - Page 84
84
Fluke 192B Service manual - Page 85
85
Fluke 192B Service manual - Page 86
86
Calibration Adjustment
5.8 Probe Calibration 5
5-19
5.8 Probe Calibration
To meet full user specifications, you need to adjust the supplied red and gray VPS200
voltage probes for optimal response.
To adjust the VPS200 probes, do the following:
1. Connect the red probe from the red Input A BNC to the banana jacks. See figure 5-9
ST8416.WMF
ST7991.WMF
Figure 5-9. 10:1 Probe Calibration Connection Figure 5-10. 10:1 Probe Calibration
2. Press , and then to open the Probe on A menu
3. Select Probe Type:
Voltage | Attenuation: 10:1 , Probe Cal...
4. Press
to start the probe calibration. A square wave appears on the screen. See
Figure 5-10 (the lower half of the screen is covered with operating instructions).
5. Adjust the trimmer screw in the probe housing until a pure square wave is displayed.
6. Press
to continue with automatic dc calibration.
The test tool automatically calibrates itself to the probe. A message indicates that he
dc calibration has been completed successfully.
7. Repeat the procedure for the gray VPS200 probe, connected from the gray Input B
BNC to the banana jacks.