Fluke 199B Service Manual

Download Service manual of Fluke 192B Accessory, Measuring Instruments for Free or View it Online on All-Guides.com. This version of Fluke 192B Manual compatible with such list of devices, as: 192B, 192C, 196C, 199B, 199C

Fluke 192B Service manual - Page 1
1
Fluke 192B Service manual - Page 2
2
Fluke 192B Service manual - Page 3
3
Fluke 192B Service manual - Page 4
4
Fluke 192B Service manual - Page 5
5
Fluke 192B Service manual - Page 6
6
Fluke 192B Service manual - Page 7
7
Fluke 192B Service manual - Page 8
8
Fluke 192B Service manual - Page 9
9
Fluke 192B Service manual - Page 10
10
Fluke 192B Service manual - Page 11
11
Fluke 192B Service manual - Page 12
12
Fluke 192B Service manual - Page 13
13
Fluke 192B Service manual - Page 14
14
Fluke 192B Service manual - Page 15
15
Fluke 192B Service manual - Page 16
16
Fluke 192B Service manual - Page 17
17
Fluke 192B Service manual - Page 18
18
Fluke 192B Service manual - Page 19
19
Fluke 192B Service manual - Page 20
20
Fluke 192B Service manual - Page 21
21
Fluke 192B Service manual - Page 22
22
Fluke 192B Service manual - Page 23
23
Fluke 192B Service manual - Page 24
24
Fluke 192B Service manual - Page 25
25
Fluke 192B Service manual - Page 26
26
Fluke 192B Service manual - Page 27
27
Fluke 192B Service manual - Page 28
28
Fluke 192B Service manual - Page 29
29
Fluke 192B Service manual - Page 30
30
Fluke 192B Service manual - Page 31
31
Fluke 192B Service manual - Page 32
32
Fluke 192B Service manual - Page 33
33
Fluke 192B Service manual - Page 34
34
Fluke 192B Service manual - Page 35
35
Fluke 192B Service manual - Page 36
36
Fluke 192B Service manual - Page 37
37
Fluke 192B Service manual - Page 38
38
Fluke 192B Service manual - Page 39
39
Fluke 192B Service manual - Page 40
40
Fluke 192B Service manual - Page 41
41
Fluke 192B Service manual - Page 42
42
Fluke 192B Service manual - Page 43
43
Fluke 192B Service manual - Page 44
44
Fluke 192B Service manual - Page 45
45
Fluke 192B Service manual - Page 46
46
Fluke 192B Service manual - Page 47
47
Fluke 192B Service manual - Page 48
48
Fluke 192B Service manual - Page 49
49
Fluke 192B Service manual - Page 50
50
Fluke 192B Service manual - Page 51
51
Fluke 192B Service manual - Page 52
52
Fluke 192B Service manual - Page 53
53
Fluke 192B Service manual - Page 54
54
Fluke 192B Service manual - Page 55
55
Fluke 192B Service manual - Page 56
56
Fluke 192B Service manual - Page 57
57
Fluke 192B Service manual - Page 58
58
Fluke 192B Service manual - Page 59
59
Fluke 192B Service manual - Page 60
60
Fluke 192B Service manual - Page 61
61
Fluke 192B Service manual - Page 62
62
Fluke 192B Service manual - Page 63
63
Fluke 192B Service manual - Page 64
64
Fluke 192B Service manual - Page 65
65
Fluke 192B Service manual - Page 66
66
Fluke 192B Service manual - Page 67
67
Fluke 192B Service manual - Page 68
68
Fluke 192B Service manual - Page 69
69
Fluke 192B Service manual - Page 70
70
Fluke 192B Service manual - Page 71
71
Fluke 192B Service manual - Page 72
72
Fluke 192B Service manual - Page 73
73
Fluke 192B Service manual - Page 74
74
Fluke 192B Service manual - Page 75
75
Fluke 192B Service manual - Page 76
76
Fluke 192B Service manual - Page 77
77
Fluke 192B Service manual - Page 78
78
Fluke 192B Service manual - Page 79
79
Fluke 192B Service manual - Page 80
80
Fluke 192B Service manual - Page 81
81
Fluke 192B Service manual - Page 82
82
Fluke 192B Service manual - Page 83
83
Fluke 192B Service manual - Page 84
84
Fluke 192B Service manual - Page 85
85
Fluke 192B Service manual - Page 86
86
Fluke 19xB-19xC-2x5C
Service Manual
4-12
Table 4-3. Volts AC Measurement Verification Points
Range 5500A output Input A&B Reading
V ac Frequency
2 mV/div
1)
(Select 10 ms/div)
Set input A&B Bandwidth 10 kHz
to prevent OL due to calibrator
noise: see step 2.
4 mV 60 Hz 3.0 mV to 5.0 mV
5 mV/div (Select 20 μs/div).
Set input A&B Bandwidth 20 MHz
10 mV 20 kHz 8.3 mV to 11.7 mV
10 mV/div 20 mV 20 kHz 18.0 mV to 22.0 mV
20 mV/div 40 mV 20 kHz 37.5 mV to 42.5 mV
50 mV/div 100 mV 20 kHz 96.0 mV to 104.0 mV
100 mV/div 200 mV 20 kHz 180 mV to 220 mV
200 mV/div 400 mV 20 kHz 375 mV to 425 mV
500 mV/div (Select 10 ms/div) 900 mV 60 Hz 877 mV to 923 mV
500 mV/div (Select 20 μs/div) 900 mV 20 kHz 863 mV to 937 mV
1 V/div 2 V 20 kHz 1.80 V to 2.20 V
2 V/div 4 V 20 kHz 3.75 V to 4.25 V
5 V/div 9 V 20 kHz 8.63 V to 9.37 V
10 V/div 20 V 20 kHz 18.0 V to 22.0 V
20 V/div 40 V 20 kHz 37.5 V to 42.5 V
50 V/div 90 V 20 kHz 86.3 V to 93.7 V
100 V/div 200 V 20 kHz 180 V to 220 V
1)
C versions only
4.6.4 Input A & B AC Coupled Lower Frequency Test
Proceed as follows to test the ac coupled input low frequency accuracy:
1. Connect the test tool to the 5500A as for the previous test (see Figure 4-3).
2. Select the following test tool setup:
Recall the created SETUP 1 (see section 4.4.3): press
, RECALL ,
select
SCREEN+SETUP 1 , press RECALL SETUP .
Press
Press
READING 1 , and select on A | V ac.
Press
READING 2 , and select on B | V ac.
Press
, then using select COUPLING AC
Press
, then using select COUPLING AC