Utilitech Twin Halogen Light UT-5592-BZ Owner's Manual

Download Owner's manual of Utilitech Twin Halogen Light UT-5592-BZ Work Light for Free or View it Online on All-Guides.com.

Utilitech Twin Halogen Light UT-5592-BZ Owner's manual - Page 1
1
Utilitech Twin Halogen Light UT-5592-BZ Owner's manual - Page 2
2
Utilitech Twin Halogen Light UT-5592-BZ Owner's manual - Page 3
3
Utilitech Twin Halogen Light UT-5592-BZ Owner's manual - Page 4
4
598-1297-01
Twin Halogen Light
1. For easy installation, select an existing light that is operated by
a wall switch for replacement.
WIRING AND FINAL ASSEMBLY
2. Put the gasket in place before connecting wires.
Questions or problems? Before returning to your retailer, call our
technical service department at 1-800-858-8501 (English speaking
only), 7:30 am to 4:30 pm, CST, Monday – Friday.
PACKAGE CONTENTS
Twin halogen light Mounting strap
Rubber plug Gasket
Wire connectors Plastic hanger
Mounting hardware 2 Bulbs (installed)
INSTALLATION INSTRUCTIONS
Estimated Installation Time: 30 minutes
Items needed for installation (not included):
Phillips and flathead screwdrivers
Pliers Wire strippers/cutters
Safety glasses Silicone caulk
Ladder
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National
Electrical Code through conduit or another acceptable
means. Contact a qualified electrician if there is any ques-
tion as to the suitability of the system.
6. Adjust the bulb holders by loosening the lock nuts (
A) and/or
lock screws (B) but do not rotate the bulb holders more than 180˚
from the factory setting. Tighten the lock nuts and lock screws
after adjusting the fixture.
7. To adjust shields, loosen set screws (C) and turn shield coun-
terclockwise about 1/3 turn and remove shield. Reinstall shield
and turn clockwise to desired position. Tighten set screw (C).
8. To replace bulbs, remove shields as above. Line up bulb pins with
bulb socket holes. Carefully push bulbs straight in. Bulbs are quite
fragile and can be easily broken if side pressure is applied.
9. Replace bulb shields.
10. Turn on the circuit breaker and light switch.
Junction Box
Gasket
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulbs and fixture
operate at high temperatures.
• Keep fixture at least 2" from combustible materials. Do
not aim at objects closer than 3 feet.
• Replace bulbs with T4 100W (max.) G8 type halogen bi-pin
120 VAC bulbs only.
WARNING: Turn power off at the circuit breaker or
fuse.
Black White
(A)
(B)
Shields
(C)
Rubber
Plug
Junction box ground wire to
green ground screw on fixture.
Mounting Strap
Mounting
Bolt
© 2007 HeathCo LLC 598-1297-01
Items Models
247587 UT-5592-BZ
247583 UT-5592-WH
3.
Connect the fixture wires to the junction box wires (black to black,
white to white, and junction box ground wire to green ground
screw on fixture.). Secure with wire connectors provided.
4. Make sure the wire connectors and wires are inside the junction
box. Secure the fixture with the screws provided.
5. If not installed on a weatherproof box or if an adaptor plate was
used, caulk the wall plate and mounting surface with silicone
weather sealant.