Delta 31 Instruction Manual

Download Instruction manual of Delta 31 Sander for Free or View it Online on All-Guides.com.

Brand: Delta

Category: Sander

Type: Instruction manual

Model: Delta 31 , Delta 731

Pages: 16 (2.13 Mb)

Download Delta 31 Instruction manual

Delta 31 Instruction manual - Page 1
1
Delta 31 Instruction manual - Page 2
2
Delta 31 Instruction manual - Page 3
3
Delta 31 Instruction manual - Page 4
4
Delta 31 Instruction manual - Page 5
5
Delta 31 Instruction manual - Page 6
6
Delta 31 Instruction manual - Page 7
7
Delta 31 Instruction manual - Page 8
8
Delta 31 Instruction manual - Page 9
9
Delta 31 Instruction manual - Page 10
10
Delta 31 Instruction manual - Page 11
11
Delta 31 Instruction manual - Page 12
12
Delta 31 Instruction manual - Page 13
13
Delta 31 Instruction manual - Page 14
14
Delta 31 Instruction manual - Page 15
15
Delta 31 Instruction manual - Page 16
16
6
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire
extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s
plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An
undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct
gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number,
the heavier the cord.
EXTENSION CORDS
Fig. D
Fig. D
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 120
up to
25 18 AWG
0-6 120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120
up to
25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120
up to
25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120
up to
25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 240
up to
50 18 AWG
0-6 240 50-100 16 AWG
0-6 240 100-200 16 AWG
0-6 240 200-300 14 AWG
6-10 240
up to
50 18 AWG
6-10 240 50-100 16 AWG
6-10 240 100-200 14 AWG
6-10 240 200-300 12 AWG
10-12 240
up to
50 16 AWG
10-12 240 50-100 16 AWG
10-12 240 100-200 14 AWG
10-12 240 200-300 12 AWG
12-16 240
up to
50 14 AWG
12-16 240 50-100 12 AWG
12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
3. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating between
150 - 250 volts, inclusive:
If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. C, the
machine will have a grounding plug that looks like the
plug illustrated in Fig. C. Make sure the machine is
connected to an outlet having the same configuration as
the plug. No adapter is available or should be used with
this machine. If the machine must be re-connected for
use on a different type of electric circuit, the re-
connection should be made by qualified service
personnel; and after re-connection, the machine should
comply with all local codes and ordinances.
IN ALL CASES, MAKE CERTAIN THE
RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. IF YOU ARE NOT SURE HAVE A
QUALIFIED ELECTRICIAN CHECK THE
RECEPTACLE.
4. Permanently connected machines:
If the machine is intended to be permanently connected,
the machine should be connected to a grounded metal
permanent wiring system, or to a system having an
equipment-grounding conductor.
Fig. C
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
THREE PHASE OPERATION
If the motor on your machine is wired for 200V, 230V, or 460V, three phase, the necessary wiring from the starter to the
power should be completed by a qualified electrician.