Dell PowerEdge C8000 Owner's Manual
Download Hardware owner's manual of Dell PowerEdge C8000 Desktop, Server for Free or View it Online on All-Guides.com.
About Your System 25
Sled Hard-Drive LEDs
The hard-drive LEDs located on the front of the C8220X sled alerts you to
the condition of the hard-drives in the sled.
Figure 1-8. Sled Hard-Drive LEDs
* This condition is not supported in LSI HBA/RAID cards. When you abort the RAID rebuild process,
the hard-drive LED blinks amber to indicate drive failure.
Condition Hard-Drive LEDs
(HDD0 to HDD7)
Green LED Amber LED
Drive bay empty/Unsupported drive is present Off Off
Drive online/access On Off
Drive identify/Preparing for removal On 250 ms
Off 250 ms
Off
Drive rebuilding On 400 ms
Off 100 ms
Off
Drive failed Off On 150 ms
Off 150 ms
Predicted drive failure (SMART) On 500 ms
Off 500 ms
Off 1000 ms
Off 500 ms
On 500 ms
Off 1000 ms
Drive rebuilding aborted* On 3000 ms
Off 9000 ms
Off 6000 ms
On 3000 ms
Off 3000 ms