Dell PowerEdge T610 Hardware Manual
Download Hardware owner's manual of Dell External OEMR T610 Computer Hardware, Desktop for Free or View it Online on All-Guides.com.
Brand: Dell
Category: Computer Hardware , Desktop , Server
Type: Hardware owner's manual
Model: Dell External OEMR T610 , Dell PowerEdge T610
Pages: 206 (10.77 Mb)
About Your System 49
The following
DIMMs should
match
in
geometry:
x
,
x
,
...
Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of data
lanes.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines."
The following
DIMMs should
match
in rank
count:
x
,
x
,
...
The following
DIMMs should
match in size:
x
,
x
,
...
The following
DIMMs should
match
in size
and geometry:
x
,
x
,
...
The following
DIMMs should
match
in size
and rank count:
x
,
x
,
...
Thermal sensor
not detected on
x
A memory module without a
thermal sensor is installed in
the specified memory slot.
Replace the memory
module. See "System
Memory."
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
System Battery."
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager." If the
problem persists, replace the
system battery. See "System
Battery."
Table 1-2. System Messages (continued)
Message Causes Corrective Actions
book.book Page 49 Tuesday, September 15, 2009 10:08 AM