Dell External OEMR R710 Technical Manual

Download Technical manual of Dell POWEREDGE R710 Computer Hardware, Desktop for Free or View it Online on All-Guides.com.

Dell POWEREDGE R710 Technical manual - Page 1
1
Dell POWEREDGE R710 Technical manual - Page 2
2
Dell POWEREDGE R710 Technical manual - Page 3
3
Dell POWEREDGE R710 Technical manual - Page 4
4
Dell POWEREDGE R710 Technical manual - Page 5
5
Dell POWEREDGE R710 Technical manual - Page 6
6
Dell POWEREDGE R710 Technical manual - Page 7
7
Dell POWEREDGE R710 Technical manual - Page 8
8
Dell POWEREDGE R710 Technical manual - Page 9
9
Dell POWEREDGE R710 Technical manual - Page 10
10
Dell POWEREDGE R710 Technical manual - Page 11
11
Dell POWEREDGE R710 Technical manual - Page 12
12
Dell POWEREDGE R710 Technical manual - Page 13
13
Dell POWEREDGE R710 Technical manual - Page 14
14
Dell POWEREDGE R710 Technical manual - Page 15
15
Dell POWEREDGE R710 Technical manual - Page 16
16
Dell POWEREDGE R710 Technical manual - Page 17
17
Dell POWEREDGE R710 Technical manual - Page 18
18
Dell POWEREDGE R710 Technical manual - Page 19
19
Dell POWEREDGE R710 Technical manual - Page 20
20
Dell POWEREDGE R710 Technical manual - Page 21
21
Dell POWEREDGE R710 Technical manual - Page 22
22
Dell POWEREDGE R710 Technical manual - Page 23
23
Dell POWEREDGE R710 Technical manual - Page 24
24
Dell POWEREDGE R710 Technical manual - Page 25
25
Dell POWEREDGE R710 Technical manual - Page 26
26
Dell POWEREDGE R710 Technical manual - Page 27
27
Dell POWEREDGE R710 Technical manual - Page 28
28
Dell POWEREDGE R710 Technical manual - Page 29
29
Dell POWEREDGE R710 Technical manual - Page 30
30
Dell POWEREDGE R710 Technical manual - Page 31
31
Dell POWEREDGE R710 Technical manual - Page 32
32
Dell POWEREDGE R710 Technical manual - Page 33
33
Dell POWEREDGE R710 Technical manual - Page 34
34
Dell POWEREDGE R710 Technical manual - Page 35
35
Dell POWEREDGE R710 Technical manual - Page 36
36
Dell POWEREDGE R710 Technical manual - Page 37
37
Dell POWEREDGE R710 Technical manual - Page 38
38
Dell POWEREDGE R710 Technical manual - Page 39
39
Dell POWEREDGE R710 Technical manual - Page 40
40
Dell POWEREDGE R710 Technical manual - Page 41
41
Dell POWEREDGE R710 Technical manual - Page 42
42
Dell POWEREDGE R710 Technical manual - Page 43
43
Dell POWEREDGE R710 Technical manual - Page 44
44
Dell POWEREDGE R710 Technical manual - Page 45
45
Dell POWEREDGE R710 Technical manual - Page 46
46
Dell POWEREDGE R710 Technical manual - Page 47
47
Dell POWEREDGE R710 Technical manual - Page 48
48
Dell POWEREDGE R710 Technical manual - Page 49
49
Dell POWEREDGE R710 Technical manual - Page 50
50
Dell POWEREDGE R710 Technical manual - Page 51
51
Dell POWEREDGE R710 Technical manual - Page 52
52
Dell POWEREDGE R710 Technical manual - Page 53
53
Dell POWEREDGE R710 Technical manual - Page 54
54
Dell POWEREDGE R710 Technical manual - Page 55
55
Dell POWEREDGE R710 Technical manual - Page 56
56
Dell POWEREDGE R710 Technical manual - Page 57
57
Dell POWEREDGE R710 Technical manual - Page 58
58
Dell POWEREDGE R710 Technical manual - Page 59
59
Dell POWEREDGE R710 Technical manual - Page 60
60
Dell POWEREDGE R710 Technical manual - Page 61
61
Dell POWEREDGE R710 Technical manual - Page 62
62
Dell POWEREDGE R710 Technical manual - Page 63
63
Dell
PowerEdge R710 Technical Guide 19
4.8.2 ReadyRails Static Rails
ReadyRails
TM
Static Rails for 4-post and 2-post racks support the following:
Toolless installation in 19‖ EIA-310-E compliant square or unthreaded round hole 4-post racks
including all generations of Dell racks
Tooled installation in 19‖ EIA-310-E compliant threaded hole 4-post and 2-post racks
See section 14 for more details.
4.9 Fans
Five hot-swappable fans are mounted in a fan gantry that is located in the chassis between the hard
drive bay and the processors. See Figure 7. Each fan has a blind mate 2x2 connector that plugs
directly into the planar. There is an additional fan integrated in each power supply to cool the power
supply subsystem and also provide additional cooling for the whole system. Single processor
configurations have four fans populated.
Figure 7. Fan Gantry
The Embedded Server Management logic in the system monitors the speed of the fans. A fan failure
or over-temperature in the system results in a notification by iDRAC6. All system fans are pulse-width
modulated fans. Redundant cooling is supported.
4.10 LCD Control Panel
The LCD control panel is located on the front of the system chassis to provide user access to
switches, display, and I/O interfaces. See Figure 8. The control panel includes the following
features:
ACPI-compliant power button with an integrated green power LED (controlled by iDRAC6)
128x20 pixel LCD with controls:
o Two navigation buttons
o Select button
o System ID button
Non-maskable Interrupt (NMI) button (recessed)
Ambient temperature sensor