Dell 8 Documentation Update

Download Documentation update of Dell PowerEdge M1000e Chassis, Computer Hardware for Free or View it Online on All-Guides.com. This version of Dell PowerEdge M1000e Manual compatible with such list of devices, as: 8, PowerEdge M600, PowerEdge M610, PowerEdge M805, POWEREDGE M905

Dell PowerEdge M1000e Documentation update - Page 1
1
Dell PowerEdge M1000e Documentation update - Page 2
2
Dell PowerEdge M1000e Documentation update - Page 3
3
Dell PowerEdge M1000e Documentation update - Page 4
4
Dell PowerEdge M1000e Documentation update - Page 5
5
Dell PowerEdge M1000e Documentation update - Page 6
6
Dell PowerEdge M1000e Documentation update - Page 7
7
Dell PowerEdge M1000e Documentation update - Page 8
8
Dell PowerEdge M1000e Documentation update - Page 9
9
Dell PowerEdge M1000e Documentation update - Page 10
10
Dell PowerEdge M1000e Documentation update - Page 11
11
Dell PowerEdge M1000e Documentation update - Page 12
12
Dell PowerEdge M1000e Documentation update - Page 13
13
Dell PowerEdge M1000e Documentation update - Page 14
14
Dell PowerEdge M1000e Documentation update - Page 15
15
Dell PowerEdge M1000e Documentation update - Page 16
16
Dell PowerEdge M1000e Documentation update - Page 17
17
Dell PowerEdge M1000e Documentation update - Page 18
18
Dell PowerEdge M1000e Documentation update - Page 19
19
Dell PowerEdge M1000e Documentation update - Page 20
20
Dell PowerEdge M1000e Documentation update - Page 21
21
Dell PowerEdge M1000e Documentation update - Page 22
22
Dell PowerEdge M1000e Documentation update - Page 23
23
Dell PowerEdge M1000e Documentation update - Page 24
24
Dell PowerEdge M1000e Documentation update - Page 25
25
Dell PowerEdge M1000e Documentation update - Page 26
26
8 Fabric OS Documentation Updates
53-1002063-03
portCfgFaultDelay
3
portCfgFaultDelay
Configures the fault delay for a single FC port.
SYNOPSIS portcfgfaultdelay --enable [slot/]port mode
portcfgfaultdelay --help
DESCRIPTION Use this command to configure the fault delay of an FC port.
In the event that the link is noisy after a host power cycle, the switch may go into a soft fault state, which
means a delay of R_A_TOV. Setting the mode value to 1 reduces the fault delay value to 1.2 seconds.
The configuration is stored in nonvolatile memory and is persistent across switch reboots or power cycle.
Use the portCfgShow command to display user-configured fault delay settings.
NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
This command is not applicable to non-FC ports.
OPERANDS This command has the following operands:
slot For bladed systems only, specifies the slot number of the port to be configured,
followed by a slash (/).
port Specifies the number of the port to be configured, relative to its slot for bladed
systems. Use switchShow for a listing of valid ports.
mode Specifies the fault delay value for the port number. This operand is required. Valid
values are one of the following:
0 Sets the fault delay to R_A_TOV (default)
1 Sets the fault delay to 1.2 seconds.
---help Displays the command usage.
EXAMPLES To set the fault delay of a port to 1.2 seconds:
switch:admin> portcfgfaultdelay 2/3 1
To display the configuration
switch:admin> portcfgshow 2/3 1
Area Number: 138
Speed Level: AUTO(HW)
Fill Word: 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF