Dell 8 Release Note

Download Release note of Dell PowerEdge M1000e Chassis, Computer Hardware for Free or View it Online on All-Guides.com. This version of Dell PowerEdge M1000e Manual compatible with such list of devices, as: PowerEdge M1000e, PowerEdge M600, PowerEdge M710, PowerEdge M805, PowerEdge M910

Dell PowerEdge M1000e Release note - Page 1
1
Dell PowerEdge M1000e Release note - Page 2
2
Dell PowerEdge M1000e Release note - Page 3
3
Dell PowerEdge M1000e Release note - Page 4
4
Dell PowerEdge M1000e Release note - Page 5
5
Dell PowerEdge M1000e Release note - Page 6
6
Dell PowerEdge M1000e Release note - Page 7
7
Dell PowerEdge M1000e Release note - Page 8
8
Dell PowerEdge M1000e Release note - Page 9
9
Dell PowerEdge M1000e Release note - Page 10
10
Dell PowerEdge M1000e Release note - Page 11
11
Dell PowerEdge M1000e Release note - Page 12
12
Dell PowerEdge M1000e Release note - Page 13
13
Dell PowerEdge M1000e Release note - Page 14
14
Dell PowerEdge M1000e Release note - Page 15
15
Dell PowerEdge M1000e Release note - Page 16
16
Dell PowerEdge M1000e Release note - Page 17
17
Dell PowerEdge M1000e Release note - Page 18
18
Dell PowerEdge M1000e Release note - Page 19
19
Dell PowerEdge M1000e Release note - Page 20
20
Dell PowerEdge M1000e Release note - Page 21
21
Dell PowerEdge M1000e Release note - Page 22
22
Dell PowerEdge M1000e Release note - Page 23
23
Dell PowerEdge M1000e Release note - Page 24
24
Dell PowerEdge M1000e Release note - Page 25
25
Dell PowerEdge M1000e Release note - Page 26
26
Dell PowerEdge M1000e Release note - Page 27
27
Dell PowerEdge M1000e Release note - Page 28
28
Dell PowerEdge M1000e Release note - Page 29
29
Dell PowerEdge M1000e Release note - Page 30
30
Dell PowerEdge M1000e Release note - Page 31
31
Dell PowerEdge M1000e Release note - Page 32
32
Dell PowerEdge M1000e Release note - Page 33
33
Dell PowerEdge M1000e Release note - Page 34
34
Dell PowerEdge M1000e Release note - Page 35
35
Dell PowerEdge M1000e Release note - Page 36
36
Dell PowerEdge M1000e Release note - Page 37
37
Dell PowerEdge M1000e Release note - Page 38
38
Dell PowerEdge M1000e Release note - Page 39
39
Dell PowerEdge M1000e Release note - Page 40
40
Dell PowerEdge M1000e Release note - Page 41
41
Dell PowerEdge M1000e Release note - Page 42
42
Dell PowerEdge M1000e Release note - Page 43
43
Dell PowerEdge M1000e Release note - Page 44
44
Dell PowerEdge M1000e Release note - Page 45
45
Dell PowerEdge M1000e Release note - Page 46
46
Dell PowerEdge M1000e Release note - Page 47
47
Dell PowerEdge M1000e Release note - Page 48
48
Dell PowerEdge M1000e Release note - Page 49
49
Dell PowerEdge M1000e Release note - Page 50
50
Dell PowerEdge M1000e Release note - Page 51
51
Dell PowerEdge M1000e Release note - Page 52
52
Dell PowerEdge M1000e Release note - Page 53
53
Dell PowerEdge M1000e Release note - Page 54
54
Dell PowerEdge M1000e Release note - Page 55
55
Dell PowerEdge M1000e Release note - Page 56
56
Dell PowerEdge M1000e Release note - Page 57
57
Dell PowerEdge M1000e Release note - Page 58
58
Dell PowerEdge M1000e Release note - Page 59
59
Dell PowerEdge M1000e Release note - Page 60
60
Dell PowerEdge M1000e Release note - Page 61
61
Dell PowerEdge M1000e Release note - Page 62
62
Close with Code Change in Fabric OS v6.4.0b
Fabric OS v6.4.1 Release Notes v1.0 Page 53 of 62
Defect ID: DEFECT000270825 Technical Severity: Medium
Summary: Expose all 64 bit port stats counter through SNMP
Symptom: 64 bit port stats is only available in CLI via portStats64Show, it's not exposed through
SNMP.
Feature: Mgmt Embedded - SNMP
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000273725 Technical Severity: Medium
Summary: Detected termination of webd and triggered call home event.
Symptom: At a customer site, webd terminated and restarted from time to time. At the same time as
the webd crash, HA status temporarily went to non-redundant, which triggered a Call Home
event. webd was killed by watchdog as webd was waiting for a reply from a busy httpd and
webd did not have a timeout mechanism. No other functional impact observed besides call
home event.
Feature: Field Escalation
Function: Management Services
Probability: Low
Found in Release: FOS6.2.0
Service Request ID: 412187
Defect ID: DEFECT000286033 Technical Severity: Medium
Summary: Bottleneckmon cannot be enabled on F-ports with "Locked G_Port" AND "Disabled E_Port"
enabled in portcfg.
Symptom: Customer is not able to enable bottleneckmon --enable <port> on switches with message
"Error: port is not an F_Port". The command works as expected after disable Locked G_Port
option. This error happens only when both "Locked G_Port " AND "Disabled E_Port"
parameters are "on" in portcfgshow.
Workaround: Disable either or both "Locked G_Port " AND "Disabled E_Port" features; However,
changing these features is disruptive.
Feature: Field Escalation
Function: OS: Configuration
Probability: High
Found in Release: FOS6.3.1
Service Request ID: 423357
Defect ID: DEFECT000298078 Technical Severity: Medium
Summary: Backup to all cleartext containers using tape application (Netbackup) in a multiplex/stream
environment results in a Brocade Encryption Switch fault
Symptom: The system will fault and result in tape flows halting.
Feature: Data Security
Function: Tape Encryption
Probability: Medium
Found in Release: FOS6.3.0
Service Request ID: 429393