Dell 8 Release Note

Download Release note of Dell PowerEdge M1000e Chassis, Computer Hardware for Free or View it Online on All-Guides.com. This version of Dell PowerEdge M1000e Manual compatible with such list of devices, as: PowerEdge M1000e, PowerEdge M600, PowerEdge M805, POWEREDGE M905, PowerEdge M910

Dell PowerEdge M1000e Release note - Page 1
1
Dell PowerEdge M1000e Release note - Page 2
2
Dell PowerEdge M1000e Release note - Page 3
3
Dell PowerEdge M1000e Release note - Page 4
4
Dell PowerEdge M1000e Release note - Page 5
5
Dell PowerEdge M1000e Release note - Page 6
6
Dell PowerEdge M1000e Release note - Page 7
7
Dell PowerEdge M1000e Release note - Page 8
8
Dell PowerEdge M1000e Release note - Page 9
9
Dell PowerEdge M1000e Release note - Page 10
10
Dell PowerEdge M1000e Release note - Page 11
11
Dell PowerEdge M1000e Release note - Page 12
12
Dell PowerEdge M1000e Release note - Page 13
13
Dell PowerEdge M1000e Release note - Page 14
14
Dell PowerEdge M1000e Release note - Page 15
15
Dell PowerEdge M1000e Release note - Page 16
16
Dell PowerEdge M1000e Release note - Page 17
17
Dell PowerEdge M1000e Release note - Page 18
18
Dell PowerEdge M1000e Release note - Page 19
19
Dell PowerEdge M1000e Release note - Page 20
20
Dell PowerEdge M1000e Release note - Page 21
21
Dell PowerEdge M1000e Release note - Page 22
22
Dell PowerEdge M1000e Release note - Page 23
23
Dell PowerEdge M1000e Release note - Page 24
24
Dell PowerEdge M1000e Release note - Page 25
25
Dell PowerEdge M1000e Release note - Page 26
26
Dell PowerEdge M1000e Release note - Page 27
27
Dell PowerEdge M1000e Release note - Page 28
28
Dell PowerEdge M1000e Release note - Page 29
29
Dell PowerEdge M1000e Release note - Page 30
30
Dell PowerEdge M1000e Release note - Page 31
31
Dell PowerEdge M1000e Release note - Page 32
32
Dell PowerEdge M1000e Release note - Page 33
33
Dell PowerEdge M1000e Release note - Page 34
34
Dell PowerEdge M1000e Release note - Page 35
35
Dell PowerEdge M1000e Release note - Page 36
36
Dell PowerEdge M1000e Release note - Page 37
37
Dell PowerEdge M1000e Release note - Page 38
38
Dell PowerEdge M1000e Release note - Page 39
39
Dell PowerEdge M1000e Release note - Page 40
40
Dell PowerEdge M1000e Release note - Page 41
41
Dell PowerEdge M1000e Release note - Page 42
42
Dell PowerEdge M1000e Release note - Page 43
43
Dell PowerEdge M1000e Release note - Page 44
44
Dell PowerEdge M1000e Release note - Page 45
45
Dell PowerEdge M1000e Release note - Page 46
46
Dell PowerEdge M1000e Release note - Page 47
47
Dell PowerEdge M1000e Release note - Page 48
48
Dell PowerEdge M1000e Release note - Page 49
49
Dell PowerEdge M1000e Release note - Page 50
50
Dell PowerEdge M1000e Release note - Page 51
51
Dell PowerEdge M1000e Release note - Page 52
52
Dell PowerEdge M1000e Release note - Page 53
53
Dell PowerEdge M1000e Release note - Page 54
54
Dell PowerEdge M1000e Release note - Page 55
55
Dell PowerEdge M1000e Release note - Page 56
56
Dell PowerEdge M1000e Release note - Page 57
57
Dell PowerEdge M1000e Release note - Page 58
58
Dell PowerEdge M1000e Release note - Page 59
59
Dell PowerEdge M1000e Release note - Page 60
60
Dell PowerEdge M1000e Release note - Page 61
61
Dell PowerEdge M1000e Release note - Page 62
62
Close with Code Change in Fabric OS v6.4.0c
Fabric OS v6.4.1 Release Notes v1.0 Page 49 of 62
Defect ID: DEFECT000307117 Technical Severity: Medium
Summary: Unable to form an ISL with AP7420 platform
Symptom: A switch running FOS6.4.0 cannot form an ISL with AP7420 platform
Workaround: Connect AP7420 to a platform that is running an earlier release of FOS than FOS6.4.0
(e.g. FOS6.3.0).
Feature: FC Services
Function: Fabric
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000308461 Technical Severity: Medium
Summary: Error in thresholding logic for port state change events prevents thresholding condition
from being reported properly.
Symptom: Fabric watch does not detect the condition and generate the correct warning messages for
port thresholding events. Customer only sees SNMP-1008 messages indicating "...Last
device change happened at HH:MM:SS..." but no thresholding event indicating the count is
above the threshold.
Feature: FABRIC WATCH
Function: CLI
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000308734 Technical Severity: Medium
Summary: Backup/Restore job fails with FICON tape read extension
Symptom: Restore job fails with invalid record id
Workaround: Disable / don't enable FICON emulation for tape jobs
Feature: FCIP
Function: FCIP I/O
Probability: Medium
Found in Release: FOS6.4.0
Defect ID: DEFECT000312245 Technical Severity: Medium
Summary: Path not brought online after path deactivation/reactivation in a large heavily loaded FICON
tape emulation configuration
Symptom: Unable to vary paths back online after offline.
Workaround: When FICON path control blocks are stuck at invalid state, disable the tunnel. If issues
are occurring with FICON emulation and ESCON devices, disable FICON Emulation. In the
case of the failed tape job, resubmit it.
Feature: FCIP
Function: Emulation
Probability: Medium
Found in Release: FOS6.4.0