Dell 8 Release Note

Download Release note of Dell PowerEdge M1000e Chassis, Computer Hardware for Free or View it Online on All-Guides.com. This version of Dell PowerEdge M1000e Manual compatible with such list of devices, as: PowerEdge M1000e, PowerEdge M605, PowerEdge M710, PowerEdge M805, PowerEdge M910

Dell PowerEdge M1000e Release note - Page 1
1
Dell PowerEdge M1000e Release note - Page 2
2
Dell PowerEdge M1000e Release note - Page 3
3
Dell PowerEdge M1000e Release note - Page 4
4
Dell PowerEdge M1000e Release note - Page 5
5
Dell PowerEdge M1000e Release note - Page 6
6
Dell PowerEdge M1000e Release note - Page 7
7
Dell PowerEdge M1000e Release note - Page 8
8
Dell PowerEdge M1000e Release note - Page 9
9
Dell PowerEdge M1000e Release note - Page 10
10
Dell PowerEdge M1000e Release note - Page 11
11
Dell PowerEdge M1000e Release note - Page 12
12
Dell PowerEdge M1000e Release note - Page 13
13
Dell PowerEdge M1000e Release note - Page 14
14
Dell PowerEdge M1000e Release note - Page 15
15
Dell PowerEdge M1000e Release note - Page 16
16
Dell PowerEdge M1000e Release note - Page 17
17
Dell PowerEdge M1000e Release note - Page 18
18
Dell PowerEdge M1000e Release note - Page 19
19
Dell PowerEdge M1000e Release note - Page 20
20
Dell PowerEdge M1000e Release note - Page 21
21
Dell PowerEdge M1000e Release note - Page 22
22
Dell PowerEdge M1000e Release note - Page 23
23
Dell PowerEdge M1000e Release note - Page 24
24
Dell PowerEdge M1000e Release note - Page 25
25
Dell PowerEdge M1000e Release note - Page 26
26
Dell PowerEdge M1000e Release note - Page 27
27
Dell PowerEdge M1000e Release note - Page 28
28
Dell PowerEdge M1000e Release note - Page 29
29
Dell PowerEdge M1000e Release note - Page 30
30
Dell PowerEdge M1000e Release note - Page 31
31
Dell PowerEdge M1000e Release note - Page 32
32
Dell PowerEdge M1000e Release note - Page 33
33
Dell PowerEdge M1000e Release note - Page 34
34
Dell PowerEdge M1000e Release note - Page 35
35
Dell PowerEdge M1000e Release note - Page 36
36
Dell PowerEdge M1000e Release note - Page 37
37
Dell PowerEdge M1000e Release note - Page 38
38
Dell PowerEdge M1000e Release note - Page 39
39
Dell PowerEdge M1000e Release note - Page 40
40
Dell PowerEdge M1000e Release note - Page 41
41
Dell PowerEdge M1000e Release note - Page 42
42
Dell PowerEdge M1000e Release note - Page 43
43
Dell PowerEdge M1000e Release note - Page 44
44
Dell PowerEdge M1000e Release note - Page 45
45
Dell PowerEdge M1000e Release note - Page 46
46
Dell PowerEdge M1000e Release note - Page 47
47
Dell PowerEdge M1000e Release note - Page 48
48
Dell PowerEdge M1000e Release note - Page 49
49
Dell PowerEdge M1000e Release note - Page 50
50
Dell PowerEdge M1000e Release note - Page 51
51
Dell PowerEdge M1000e Release note - Page 52
52
Dell PowerEdge M1000e Release note - Page 53
53
Dell PowerEdge M1000e Release note - Page 54
54
Dell PowerEdge M1000e Release note - Page 55
55
Dell PowerEdge M1000e Release note - Page 56
56
Dell PowerEdge M1000e Release note - Page 57
57
Dell PowerEdge M1000e Release note - Page 58
58
Dell PowerEdge M1000e Release note - Page 59
59
Dell PowerEdge M1000e Release note - Page 60
60
Dell PowerEdge M1000e Release note - Page 61
61
Dell PowerEdge M1000e Release note - Page 62
62
Fabric OS v6.4.1 Release Notes v1.0 Page 20 of 62
FOS Features
FOS Features FOS Features
FOS Features
(supported in interopmode 0)
FOS v6.4
FOS v6.4FOS v6.4
FOS v6.4
IM = Interopmode
IM = InteropmodeIM = Interopmode
IM = Interopmode
IM 2
IM 2IM 2
IM 2
IM 3
IM 3IM 3
IM 3
Adaptive Network
ing: QoS
No
No
Adaptive Networking: Ingress Rate Limiting
No*
No*
Advanced Performance Monitoring (APM)
No*
No*
APM: TopTalkers
No*
No*
Admin Domains
No
No
Secure Fabric OS
5
N/A
N/A
Fabric Watch
Yes
Yes
Ports on Demand (POD)
Yes
Yes
NPIV
Yes
Yes
T
imer Server function (NTP)
No
No
Open E_Port
6
N/A
N/A
Broadcast Zoning
No
No
FDMI
No
No
Remote Switch
No
No
Port Mirroring
Yes
Yes
Extended Fabrics
Yes
Yes
7
Alias Server
No
No
Platform Service
No
No
FCIP (VE_Ports)
Yes
Yes
IPFC (IP over FC)
Yes
8
Yes
8
M
-
EOS ALPA 0x13 configuration
Yes
Yes
VE to VEX Port
Yes
Yes
Integrated Routing
9
Yes
9
Yes
Domain Offset Support
Yes
Yes
239 Domain Support (available on Mi10k only)
N/A
Yes
Masterless F_PORT Trunking (AG connect to FOS switches only)
Yes
Yes
F
C10
-
6
-
to
-
FC10
-
6 ISL
Yes
Yes
RASLOG Events on duplicate WWNs
Yes
Yes
Virtual Fabrics
Yes
Yes
Logical Fabric using LISLs (XISLs in Base Fabric)
No
No
Port Fencing
Yes
Yes
Bottleneck Detection
Yes
Yes
Lossless DLS
No
No
* indicates the feature is available but not officially tested or supported
1. Requires M-EOS 9.7 or later for redirection between devices attached to FOS switches, M-EOS 9.8 for
redirection between devices attached to M-EOS switches, M-EOS 9.9 for use in McDATA Open Fabric
Mode. Supported M-EOS platforms include M4400, M4700, M6140, and Mi10k.
2. Only allowed between FOS-based switches.
3. DPS is supported outbound from FOS-based switches. (M-EOS can provide reciprocal load balancing
using OpenTrunking).
4. SCC policies only supported in conjunction with L2 Fabric Binding support.
5. Not supported in FOS 6.0 or later.
6. Mode 3 only qualified with M-EOS switches.
7. Not on FCR.
8. Only supported locally within the FOS switch.
9. All routers (EX_Ports) must reside in a backbone fabric running in interopmode 0 only. Only edge fabrics
with devices imported to the backbone fabric or other edge fabrics may be operating in IM2 or IM3.