Fabric OS FCIP Administrator’s Guide 81
53-1001766-01
Portshow command usage
4
Portshow command usage
The portshow command can be used to display operational information for 7800 switches, FX8-24
blades, 7500 switches, and FR4-18i blades. The Fabric OS Command Reference Manual and the
man pages provide complete descriptions of portshow command syntax and options. The following
sections identify a few specific outputs that may be useful for maintenance and troubleshooting.
Displaying IP interfaces
The following example shows IP interface information for a 7800 switch.
switch:admin> portshow ipif ge5
portshow ipif ge5
Port: ge5
Interface IP Address NetMask Effective MTU Flags
--------------------------------------------------------------
0 105.80.0.150 255.0.0.0 1500 U R M
1 105.80.0.151 255.0.0.0 1500 U R M
2 105.80.0.152 255.0.0.0 1500 U R M
3 105.80.0.153 255.0.0.0 1500 U R M
Displaying IP routes
The following example shows IP route information for a 7800 switch.
switch:admin> portshow iproute ge5
Port: ge5
IP Address Mask Gateway Metric Flags
-------------------------------------------------------------
105.0.0.0 255.0.0.0 * 0 U C
105.80.0.151 255.255.255.255 * 0 U C
105.80.0.152 255.255.255.255 * 0 U C
105.80.0.153 255.255.255.255 * 0 U C
105.83.0.150 255.255.255.255 * 0 U H L
105.83.0.151 255.255.255.255 * 0 U H L
105.83.0.152 255.255.255.255 * 0 U H L
105.83.0.153 255.255.255.255 * 0 U H L
Flags: U=Usable G=Gateway H=Host C=Created(Interface) S=Static
L=LinkLayer(Arp)
Displaying FCIP tunnel information
The following example of the portshow fciptunnel command is used most often to determine
fciptunnel status. The output from the command includes 7500, FR4-18i, 7800 and FX8-24 FCIP
tunnel summary data.
switch:admin> portshow fciptunnel all -c
-------------------------------------------------------------------------------
Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met
-------------------------------------------------------------------------------
16 - Up ----T 7h15m42s 0.00 0.00 2 - -
16 0 ge2 Up ----s 7h15m42s 0.00 0.00 2 200/1000 0
16 1 ge3 Up ----s 7h15m31s 0.00 0.00 3 200/1000 0
23 - Disable ---F- 0s 0.00 0.00 0 - -