170 Fabric OS Message Reference
53-1001767-01
ESW-1004
24
ESW-1004
Message <timestamp>, [ESW-1004], <sequence-number>,, ERROR, <system-name>,Blade attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the blade has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1005
Message <timestamp>, [ESW-1005], <sequence-number>,, ERROR, <system-name>,Diag attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the Diag blade attach command has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1006
Message <timestamp>, [ESW-1006], <sequence-number>,, WARNING, <system-name>, HA state out
of sync: Standby CP (ver = <standby SWC version>) does not support NPIV
functionality. (active ver = <active SWC version>, NPIV devices = <'1' if NPIV
devices exist; Otherwise '0'>).
Probable Cause Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged into the fabric.
Recommended
Action
Load a firmware version on standby that supports NPIV functionality, using the firmwareDOwnload
command.
Severity WARNING
ESW-1007
Message <timestamp>, [ESW-1007], <sequence-number>,, WARNING, <system-name>,Switch port
<port number> disabled due to \"<disable reason>\".
Probable Cause Indicates that the switch port is disabled due to the reason displayed in the message.
Recommended
Action
Based on the disable reason displayed, take appropriate action to restore the port. Insufficient
frame buffers: Reduce the distance or speed settings for the port to reduce the buffer requirement
of the link. Alternatively, one or more ports in the port group must be disabled to make more
buffers available for the link. Refer to the Fabric OS Administrator's Guide for more information.