(LRX Series - New Construction Frame)
Installation Guide
BEFORE YOU BEGIN
Read these instructions completely and carefully.
NOTICE
Lamp Housings LRXS4, LRXS6, LRXS8 may be assembled with part FRAMExS. When Lamp Housings LRXS4, LRXS6, LRXS8 is assembled with Part
FRAMExS the final assembly complies with UL 1598 category IFAO recessed luminaire requirements. LRX products are suitable for wet location
covered ceiling only.
Les boîtiers de lampes LRXS4, LRXS6, LRXS8 peuvent être montés avec la pièce FRAMExS. Lorsque les boîtiers des lampes LRXS4, LRXS6, LRXS8
sont montés avec la pièce FRAMExS, le montage inal respecte les exigences des luminaires encastrés de la catégorie IFAO de la norme UL 1598.
LRX produits conviennent pour emplacement humide couverte au plafond uniquement.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
The LED luminaire must be connected
to the mains supply according to its
ratings on the product label.
Grounding Instructions
The grounding and bonding of the overall system
shall be done in accordance to local electric code
of the country where the luminaire is installed.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG or 14 AWG for continuous runs.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG ou 14 AWG pour les rangées continues.