The repeat panel duplicates all of the control panel
indications and the essential controls.
The repeat panel has its own mains derived power
supply with battery for standby power in the event
of mains supply failure. A lockable front door
prevents unauthorised access to fire alarm controls
but allows all of the indicators to be seen. The
panel is designed for semi-flush or surface
mounting and facilitates both rear and top cable
entry points.
This repeat panel can be installed on a loop circuit
of an EN or BS Vigilon fire detection and alarm
system. It can be sited near an entry or exit point
of a building and fit in with the loop cable routing.
Compatibility
The repeat panel is compatible with system control
panel having card and software below:
Control panel
CARD
Control Panel Software
EN54 BS5839
LCC
³ V4.00 ³ 3.42
LPC
New Shorter
Card ONLY
³ V4.19 ³ 3.90
MCC
³ V4.11
-
MCB
³ V4.21
-
³ means equal to or greater than
Technical Data
Panel dimensions height 403mm, width 338mm,
depth 101mm
Weight 9Kg with battery (approximate)
Storage temperature -10°C to +55ºC
Operating
temperature
0°C to +45ºC
Relative humidity
(Non condensing)
Up to 90% temperature
+5°C to +45°C
Battery 12V 7Ah sealed lead acid
Mains operating
voltage
230V -15% +10% 50/60Hz
Rated Current 0.2A
Emission BS EN61000-6-3 : 2001
Immunity BS EN50130-4 : 1996 : Part 4
LVD BS EN 60950-2006
Ingress protection IP31 (estimated)
Colour Door - Pantone 422
Back box - Graphite Grey (RAL 7024)
Controls
(with door closed)
Access level 1
Next and Previous buttons operable
during fire condition only.
Control buttons
(with door open)
Access level 2
Sound Alarms, Silence Alarms, Reset
Fire, Cancel Fault Buzzer, Verify,
F1-F4, Menu On/Off and U1-U4.
Indicators Fire, Verify, Power, Fault, Power Fault,
System Fault, Delay and CB253/254.
EN panel only: Sounder, Sounder,
Delay, Disablement Test and 32-Fire
Zone LEDs.
BS panel only: Commission and
Warning.
Display: 8 lines 40 characters per line,
back-lit LCD.
Loop connection 3-way connection to a loop circuit
EN54-17 data
Fire detection and
fire alarm system
short circuit isolators
V
max 42V Vnom 40V
V
min 24V VSO max 16V
V
SO min 8V IC max 0.4A
I
S max 1A IL max 20mA
Z
C max 0.1W
4188-839_issue 8_07/14_pt1_EN/BS new Repeat_inst 1
Data and installation
Vigilon Repeat panel (EN/BS)
VIG-RPT-72
by Honeywell
Vigilon Fire System
GENT 2010
Panel healthy