SiXSHOCK
Wireless Shock/Door/Window Sensor
Installation Instructions
The SiXSHOCK is a 3-zone wireless
shock/door/window sensor is intended for use with
Honeywell controls that support SiX™ series
devices.
It provides
Reed switch/magnet zone
External wired contact zone
Built-in shock sensor zone
Typical shock protection area:
10 - 12 sq. ft. / 5 - 6 foot radius (3.05m 3.66m /
1.52m 1.83m radius)
The coverage area can vary depending on the
mounting surface.
Open the SiXSHOCK
Firmly slide the top and bottom housings in
opposite directions and pull them apart to open the
device.
Installation Options
The SiXSHOCK can be mounted with several
options:
Loop 1: Built-in shock sensor alarm status
Loop 2: Normally closed, built in reed switch,
used with the included magnet (1)
Loop 3: Externally wired, closed-circuit contact
loop connected to the Terminal Block
NOTE:Wiring limit is 3ft.
Gap specifications:
a. Make gap is at least 0.8" (1)
b. Break gap is at least 0.95" (1)
(reduced about 30% for steel)