Models Watts Dimensions Ratings
THH 1500, THH 1500SS 1550 850 x 170 x 40mm 230V 50Hz a.c
THH 2400, THH 2400SS 2500 1330 x 170 x 40mm 230V 50Hz a.c
THH 3200, THH 3200SS 3350 1770 x 170 x 40mm 230V 50Hz a.c
Note: THH series HEATSTRIPS have an IPX5 rating for protection against water ingress. Prior to
installing and operating the heater, read these instructions carefully and retain for future reference.
Preparation
The THH Series HEATSTRIPS are high intensity Radiant Strip Heaters designed for Domestic / 1.
Commercial heating applications within indoor or outdoor undercover areas, and should not be
used for any other purpose.
Before commencing installation, make sure the electrical supply voltage is the same as that 2.
shown on the rating plate of the heater.
The heater is fi tted with a length of fl exible cable for electrical connection. The heater should 3.
be connected as a fi xed installation by a licensed electrical person, according to the relevant
electrical standards.
All pole disconnection from the supply mains must be provided in fi xed wiring in accordance with 4.
the wiring rules.
This appliance must be earthed.5.
The heater is required to be fi tted with an “ON/OFF isolation switch and can also be controlled 6.
via thermostat, timer or dimmer type control. A wall switch should be installed on fi xed wire
installations. Optional connection to a R.C.D is recommended.
If the heater or supply lead is damaged, the appliance must be returned to the distributor / 7.
manufacturer for repair.
Installation Location
For both wall and ceiling mounting, the lowest part of the heater must be located a minimum of *
2100mm above fl oor level.
The heater must not be closer than 300mm to adjacent walls, with a minimum of 60mm *
between back of heater and any surface.
Allow 1000mm from the bottom of the heater to any surface below. *
Do not allow thermal insulation, cables, fl ammable materials or any other items to come into *
contact with any surface of the heater; purpose design brackets excluded.
The heater must not be located immediately below a socket outlet.*
If installed in wet areas, the heater must be installed so that switches and other controls cannot *
be touched by persons in the bath or shower.