Fisher & Paykel CoolDrawer RB90S Installation Instructions

Download Installation instructions of Fisher & Paykel CoolDrawer RB90S LCD Drawer, Refrigerator for Free or View it Online on All-Guides.com.

Fisher & Paykel CoolDrawer RB90S Installation instructions - Page 1
1
Fisher & Paykel CoolDrawer RB90S Installation instructions - Page 2
2
Important!
Disconnect power to surrounding appliances before preparing cavity.
Recommended to allow the vertical removal of the refrigerator bins.
WARNING!
Electrical shock hazard
Disconnect product from main power supply before installing appliance.
Failure to do so may result in electrical shock or death
Important safety precautions!
Installation of the CoolDrawer requires competent mechanical and electrical skills.
Be sure to leave these Instructions with the Customer.
Installation must comply with your local building and electricity regulations.
At the completion of the CoolDrawer installation, the Installer must perform the Final Check List.
Remove all packaging materials supplied with the CoolDrawer.
The CoolDrawer is manufactured for indoor use only.
Important!
SAVE THESE INSTRUCTIONS
The model shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website
www.fisherpaykel.com or contact your local Fisher & Paykel dealer.
SAFETY AND WARNINGS
WARNING!
Cut hazard
Take care – panel edges are sharp.
Failure to use caution could result in injury or cuts.
1
2
The CoolDrawer MUST be installed to allow for future removal from the enclosure if service is required.
Do not seal the CoolDrawer into the cabinetry with silicone or glue. Doing so will make future servicing
difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in
product, nor for repairing any damage that may be incurred by doing this.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the
power supply cord.
Failure to install the CoolDrawer correctly will invalidate any warranty or liability claims.
If the power supply cord is damaged, it must be replaced. Parts are available from your Fisher & Paykel
Appliances Authorised Service Centre.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capacities, or lack of experience and knowledge unless they are supervised or given instruction
concerning use of the appliance.
Cabinetry must be sufficiently robust to support a combined product and food load of 100 kg. Bearers may
be required to support the internal shelf.
Before you install the CoolDrawer, please ensure that
The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after
installation.
The switched power outlet must be located outside the cavity, within 1400 mm from the CoolDrawer
cavity if situated on the left-hand side of the cavity and within 850 mm if situated on the right-hand side
of the cavity.
The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit
through.
PRODUCT DIMENSIONS
PARTS SUPPLIED
4
5
CAVITY PREPARATION
CoolDrawer
Installation instructions
RB90S model
FRAMELESS CABINETRY
WARNING!
Tipping hazard
Do not operate this appliance until it has been securely anchored inside the cabinetry.
The cabinet must be securely anchored to the floor.
Failure to use caution could result in injury or cuts.
Product dimensions (mm)
CoolDrawer
RB90S
A
overall height of product (inc. installation brackets)
640
B
overall width of product
855
C
overall depth of product (excl. drawer panel; inc. power cord)
557
D
depth of drawer (open) (excl. handle)
520
Installation diagrams for illustration purposes only
A
D
H
Cabinetry dimensions (mm)
CoolDrawer
RB90S
A
overall width of cabinetry frame
900
B
minimum inside width of cabinetry frame
864
C
internal height of cabinetry to top of spacer block
644
D
internal height of cabinetry*
(to allow for product and outlet duct height)
min. 665
max. 764
E
minimum height of toe kick
75
F
minimum depth** of toe kick
40
G
minimum distance from front of cabinetry to rear wall
560
H
width of spacer blocks
50
*Minimum internal height of cabinetry can be 644 mm if outlet duct is not used.
**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)
Minimum clearances (mm)
2 mm
13 mm
E
B
C
D
G
F
F
C
G
Installation
trims (2)
Installation brackets
(left-hand and right-
hand side) (2)
Outlet duct (1)Trim brackets (4) Drawer Panel
attachment
hooks (3)
Power
cord (1)
Note: Services can be located
either side of CoolDrawer.
max.
20 mm
max. 850 mm
min. ø50 mm
Benchtop
Panel
min. 535 mm
Installation diagrams for illustration purposes only
Drawer Panel
16-20 mm
False Panel
(896 mm)
height of False Panel
4 mm
6
INTEGRATED PANEL PREPARATION
A
B
min.
130 mm
Phillips 16 mm
wood screw (6)
Pan Head
16 mm
screw (12)
Pan Head
16 mm
screw (2)
Phillips
16 mm
wood
screws (6)
min. 535mm
min. 130mm
height of
Drawer
Panel
3
CABINETRY DIMENSIONS
Shows cutout if cabinetry
depth at minimum
550 mm
Benchtop
Drawer panel
False panel
A
D
E
C
B
Integrated Panel material
16 - 20 mm panel thickness (18 mm recommended).
Maximum weight of 7 kg.
Adequately sealed to withstand moisture (50
O
C @ 80% RH)
Height of Drawer Panel
The following information is required to correctly define your drawer panel height:
Dimension Data Source
A Clearance between top of Drawer panel and underside Your kitchen designer
of benchtop
B Height between underside of cabinetry ceiling Your kitchen designer
and underside of benchtop
C Internal height of cabinetry to top of spacer block 644 mm
D Drawer panel height Calculated from A, B, C & E
E Bottom face of Drawer panel to top of spacer block Your kitchen designer
(to ensure that bottom cover of product is not exposed) (Min. 154 mm, Max. 184 mm)
To calculate D complete the following equation:
D = C + B - A - E
i.e. For the F&P prefinished panel:
476 mm = 644 mm + 18 mm - 2 mm - 184 mm
Height of the False Panel
Determine the height of the false panel according to your individual kitchen cabinetry
requirements maintaining a 4 mm gap between panels.
F&P prefinish panel width is 896 mm assuming a 2 mm clearance either side of panel
height (D) is 476 mm.
Note: B must be min. 16 mm to ensure adequate clearance to benchtop.
An internal shelf can be used as an alternative to spacer blocks to
position the product at the correct height. In this case additional
cutouts will be required. Refer to Step 7.
SIDE VIEW