Amana A1200S Service

Download Service of Amana A1200S Microwave Oven for Free or View it Online on All-Guides.com. This version of Amana A1200S Manual compatible with such list of devices, as: FSP10.C, FSP10.D, P1302101M, P4020004901, P4020008302

Amana A1200S Service - Page 1
1
Amana A1200S Service - Page 2
2
Amana A1200S Service - Page 3
3
Amana A1200S Service - Page 4
4
Amana A1200S Service - Page 5
5
Amana A1200S Service - Page 6
6
Amana A1200S Service - Page 7
7
Amana A1200S Service - Page 8
8
Amana A1200S Service - Page 9
9
Amana A1200S Service - Page 10
10
Amana A1200S Service - Page 11
11
Amana A1200S Service - Page 12
12
Amana A1200S Service - Page 13
13
Amana A1200S Service - Page 14
14
Amana A1200S Service - Page 15
15
Amana A1200S Service - Page 16
16
Amana A1200S Service - Page 17
17
Amana A1200S Service - Page 18
18
Amana A1200S Service - Page 19
19
Amana A1200S Service - Page 20
20
Amana A1200S Service - Page 21
21
Amana A1200S Service - Page 22
22
Amana A1200S Service - Page 23
23
Amana A1200S Service - Page 24
24
Amana A1200S Service - Page 25
25
Amana A1200S Service - Page 26
26
Amana A1200S Service - Page 27
27
Amana A1200S Service - Page 28
28
Amana A1200S Service - Page 29
29
Amana A1200S Service - Page 30
30
Amana A1200S Service - Page 31
31
Amana A1200S Service - Page 32
32
Amana A1200S Service - Page 33
33
Amana A1200S Service - Page 34
34
Amana A1200S Service - Page 35
35
Amana A1200S Service - Page 36
36
Amana A1200S Service - Page 37
37
Amana A1200S Service - Page 38
38
Amana A1200S Service - Page 39
39
Amana A1200S Service - Page 40
40
Amana A1200S Service - Page 41
41
Amana A1200S Service - Page 42
42
Amana A1200S Service - Page 43
43
Amana A1200S Service - Page 44
44
Amana A1200S Service - Page 45
45
Amana A1200S Service - Page 46
46
Amana A1200S Service - Page 47
47
Amana A1200S Service - Page 48
48
Amana A1200S Service - Page 49
49
Amana A1200S Service - Page 50
50
Amana A1200S Service - Page 51
51
Amana A1200S Service - Page 52
52
Amana A1200S Service - Page 53
53
Amana A1200S Service - Page 54
54
Amana A1200S Service - Page 55
55
Amana A1200S Service - Page 56
56
Amana A1200S Service - Page 57
57
Amana A1200S Service - Page 58
58
Amana A1200S Service - Page 59
59
Amana A1200S Service - Page 60
60
Amana A1200S Service - Page 61
61
Amana A1200S Service - Page 62
62
Amana A1200S Service - Page 63
63
Amana A1200S Service - Page 64
64
Amana A1200S Service - Page 65
65
Amana A1200S Service - Page 66
66
Amana A1200S Service - Page 67
67
Amana A1200S Service - Page 68
68
Amana A1200S Service - Page 69
69
Amana A1200S Service - Page 70
70
Amana A1200S Service - Page 71
71
Amana A1200S Service - Page 72
72
Amana A1200S Service - Page 73
73
Amana A1200S Service - Page 74
74
Amana A1200S Service - Page 75
75
RE220002 Rev. 6 16
Test Procedures
High voltages are present during the cook cycle.
Extreme caution should be observed at all times.
Before touching any oven components or wiring,
always
unplug the oven from its power source and
discharge the
capacitor
by shorting across the capacitor terminals with an insulated handle screwdriver.
DANGER
!
Low Voltage (Controller) Transformer Test
An operational test can be performed to verify proper
operation of the low voltage transformer.
1. Disconnect power to the oven and remove the
control panel assembly.
2. With a voltmeter set to appropriate VAC scale,
perform the following test set-ups, measure and
record the voltage indicated on the meter.
WARNING
!
Do not touch any oven components or wiring during
oven operation.
TEST SET-UPS TEST POINTS NORMAL VOLTAGE (Approximate)
Attach meter leads to wire harness
test points A - B, apply power to
oven and open oven door.
A & B
120 VAC on all models except
FS14.EVP.00, FS14EVP.A,
and FS14EVP.B which
is 208 - 230 VAC.
Disconnect power and remove L.V.
transformer connector attached to
the control circuit board and attach
meter leads into harness side of
connector at test points shown in
chart. Apply power to oven and
open oven door.
2 (Blue) - 4 (Brown
1 (Black) - 6 (Orange)
5 (Yellow) - 6 (Orange)
2.6 VAC 23 VAC 46 VAC
FS14EVP,
FS16EVP
A1200S, A1225S, FSP10,
FSP-11, VEND10, VEND11
Procedure A:
If the proper AC voltages were measured
as shown on the test chart, the low voltage transformer
operation is normal.
Procedure B:
If abnormal reading was measured at test
points 2-4, 1-6, 5-6, as indicated on the test chart but
normal voltage was measured at test points A-B, replace
low voltage transformer. If no voltage was measured at
test points A-B, check wire connections and circuit
diagnosis for other possible causes.