Maytag ACM1580AB Service Manual

Download Service manual of Maytag ACM1580AB Microwave Oven for Free or View it Online on All-Guides.com. This version of Maytag ACM1580AB Manual compatible with such list of devices, as: ACM1580AB, ACM1580AS, JMC9158AAB, JMC9158AAS, JMC9158AAW

Maytag ACM1580AB Service manual - Page 1
1
Maytag ACM1580AB Service manual - Page 2
2
Maytag ACM1580AB Service manual - Page 3
3
Maytag ACM1580AB Service manual - Page 4
4
Maytag ACM1580AB Service manual - Page 5
5
Maytag ACM1580AB Service manual - Page 6
6
Maytag ACM1580AB Service manual - Page 7
7
Maytag ACM1580AB Service manual - Page 8
8
Maytag ACM1580AB Service manual - Page 9
9
Maytag ACM1580AB Service manual - Page 10
10
Maytag ACM1580AB Service manual - Page 11
11
Maytag ACM1580AB Service manual - Page 12
12
Maytag ACM1580AB Service manual - Page 13
13
Maytag ACM1580AB Service manual - Page 14
14
Maytag ACM1580AB Service manual - Page 15
15
Maytag ACM1580AB Service manual - Page 16
16
Maytag ACM1580AB Service manual - Page 17
17
Maytag ACM1580AB Service manual - Page 18
18
Maytag ACM1580AB Service manual - Page 19
19
Maytag ACM1580AB Service manual - Page 20
20
Maytag ACM1580AB Service manual - Page 21
21
Maytag ACM1580AB Service manual - Page 22
22
Maytag ACM1580AB Service manual - Page 23
23
Maytag ACM1580AB Service manual - Page 24
24
Maytag ACM1580AB Service manual - Page 25
25
Maytag ACM1580AB Service manual - Page 26
26
Maytag ACM1580AB Service manual - Page 27
27
Maytag ACM1580AB Service manual - Page 28
28
Maytag ACM1580AB Service manual - Page 29
29
Maytag ACM1580AB Service manual - Page 30
30
Maytag ACM1580AB Service manual - Page 31
31
Maytag ACM1580AB Service manual - Page 32
32
Maytag ACM1580AB Service manual - Page 33
33
Maytag ACM1580AB Service manual - Page 34
34
Component Specifications
CAUTION
!
To avoid electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor before
servicing, unless testing requires power.
©2005 Maytag Services
16026267 9
Illustration Component Testing Results
Fan motor
Disconnect wires from terminals.
Measure continuity from:
Terminal to terminal..........................
Approximately 49
Heater fan motor
Disconnect wires from terminals.
Measure continuity from:
Terminal to terminal..........................
Approximately 29.5
Relay 2
Disconnect wires from terminals.
Measure resistance at terminals:
Idle state...........................................
Microwave state ...............................
Infinite
Continuity
Relay 4
Disconnect wires from terminals.
Measure voltage at terminals:
Idle state...........................................
Convection state...............................
Infinite
Continuity
COM
NC
NO
Oven lamp switch
Disconnect wires from terminals.
Measure continuity from:
COM to NO.......................................
Open infinite, Closed continuity
Thermal cutout
Disconnect wires from terminals.
Measure resistance across terminals...
Oven TCO
This TCO will reset by itself:
ACM1580....................................
JMC9158 ....................................
Continuity
Open at 230°F and closed at 140°F
Open at 302°F and closed at 140°F
Thermistor
Disconnect wires from terminals.
At room temperature. (68°F 86°F)
Measure resistance across terminals.
Terminal 1 3 .................................
Approximately 255 K
Sensor assembly
Disconnect wires from terminals.
Measure resistance across terminals.
Terminal 1 3 .................................
Terminal 1 2 .................................
Terminal 2 3 .................................
Approximately 3 K
Approximately 6 K
Approximately 3 K
COM
NC
NO
Monitor interlock
Disconnect wires from terminals.
Measure resistance at following
terminals:
NC COM........................................
NOTE: When line fuse is blown replace
monitor, primary, and secondary
interlock switches.
Door open continuity, door closed
infinite.
COM
NC
NO
Primary interlock
Disconnect wires from terminals.
Measure resistance at following
terminals:
NO COM........................................
NOTE: When line fuse is blown replace
monitor, primary, and secondary
interlock switches.
Door open infinite, door closed
continuity.
COM
NC
NO
Secondary interlock
Disconnect wires from terminals.
Measure resistance at following
terminals:
NC COM........................................
NOTE: When line fuse is blown replace
monitor, primary, and secondary
interlock switches.
Door open continuity, door closed
infinite.