Samsung CK95 Service Manual

Download Service manual of Samsung CK95 Microwave Oven for Free or View it Online on All-Guides.com. This version of Samsung CK95 Manual compatible with such list of devices, as: CK95, CK96T, CK97B, CK98F

Samsung CK95 Service manual - Page 1
1
Samsung CK95 Service manual - Page 2
2
Samsung CK95 Service manual - Page 3
3
Samsung CK95 Service manual - Page 4
4
Samsung CK95 Service manual - Page 5
5
Samsung CK95 Service manual - Page 6
6
Samsung CK95 Service manual - Page 7
7
Samsung CK95 Service manual - Page 8
8
Samsung CK95 Service manual - Page 9
9
Samsung CK95 Service manual - Page 10
10
Samsung CK95 Service manual - Page 11
11
Samsung CK95 Service manual - Page 12
12
Samsung CK95 Service manual - Page 13
13
Samsung CK95 Service manual - Page 14
14
Samsung CK95 Service manual - Page 15
15
Samsung CK95 Service manual - Page 16
16
Samsung CK95 Service manual - Page 17
17
Samsung CK95 Service manual - Page 18
18
Samsung CK95 Service manual - Page 19
19
Samsung CK95 Service manual - Page 20
20
Samsung CK95 Service manual - Page 21
21
Samsung CK95 Service manual - Page 22
22
Samsung CK95 Service manual - Page 23
23
Samsung CK95 Service manual - Page 24
24
Samsung CK95 Service manual - Page 25
25
Samsung Electronics5-4
Alignment and Adjustments
1) Pour 275±15cc of 20±5ûC(68±9ûF) water in a
beaker which is graduated to 600cc, and place
the beaker in the center of the oven.
2) Start to operate the oven and measure the
leakage by using a microwave energy survey
meter.
3) Set survey meter with dual ranges to 2,450MHz.
4) When measuring the leakage, always use the 2
inch spacer cone with the probe. Hold the probe
perpendicular to the cabinet door. Place the
spacer cone of the probe on the door and/or
cabinet door seam and move along the seam, the
door viewing window and the exhaust openings
moving the probe in a clockwise direction at a rate of 1 inch/sec. If the leakage testing of the cabinet door
seam is taken near a corner of the door, keep the probe perpendicular to the areas making sure that the
probe end at the base of the cone does not get closer than 2 inches to any metal. If it gets closer than 2
inches, erroneous readings may result.
5) Measured leakage must be less than 4mW/cm
2
, after repair or adjustment.
A
u
t
o
A
u
t
o
1min+
/
GB/F/D/E/I/NL/R
Auto
/ C
5-12 Leakage Measuring Procedure
5-9 Procedure for Measurement of Microwave Energy Leakage
5-11Note on Measurement
5-10 Check for Microwave Leakage
5-13-1 Record keeping and notification after measurement
1) After adjustment and repair of a radiarion preventing device, make a repair record for the measured
values, and keep the data.
2) If the radiation leakage is more than 4 mW/cm
2
after determining that all parts are in good condition,
functioning properly and the identical parts are replaced as listed in this manual notift that fact to ;
CENTRAL SERVICE CENTER
5-13-2 At least once a year have the microwave energy survey meter checked for accuracy by its manufacturer.
1. Remove the outer panel.
2. Pour 275±15cc of 20±5ûC(68±9ûF) water in a
beaker which is graduated to 600cc, and
place the beaker in the center of the oven.
3. Start the oven at the highest power level.
4. Set survey meter dual ranges to 2,450MHz.
5. Using the survey meter and spacer cone as
described above, measure arnear the
opening of magnetron, the surface of the air
guide and the surface of the wave guide as
shown in the following photo.( but avoid the
high voltage components.) The neading
should be less than 4mW/cm
2
.
1) Do not exceed the limited scale.
2) The test probe must be held on the grip of the handle, otherwise a false reading may result when the
operator's hand is between the handle and the probe.
3) When high leakage is suspected, do not move the probe horizontally along the oven surface; this may
cause damage to the probe.
4) Follow the recommendation of the manufacturer of the microwave energy survey meter.
Maximum allowable leakage is 5mW/cm
2
.
4mW/cm
2
is used to allow for measurement and meter accuracy
WARNING
AVOID THE HIGH VOLTAGE COMPONENTS.