Kenmore 767. 8703000 Service Manual

Download Service manual of Kenmore 767. 8703000 Microwave Oven for Free or View it Online on All-Guides.com. This version of Kenmore 767. 8703000 Manual compatible with such list of devices, as: 767. 8703000, 767. 8803000, 767. 8903000, 767. 8903400, 767. 8903900

Kenmore 767. 8703000 Service manual - Page 1
1
Kenmore 767. 8703000 Service manual - Page 2
2
Kenmore 767. 8703000 Service manual - Page 3
3
Kenmore 767. 8703000 Service manual - Page 4
4
Kenmore 767. 8703000 Service manual - Page 5
5
Kenmore 767. 8703000 Service manual - Page 6
6
Kenmore 767. 8703000 Service manual - Page 7
7
Kenmore 767. 8703000 Service manual - Page 8
8
Kenmore 767. 8703000 Service manual - Page 9
9
Kenmore 767. 8703000 Service manual - Page 10
10
Kenmore 767. 8703000 Service manual - Page 11
11
Kenmore 767. 8703000 Service manual - Page 12
12
Kenmore 767. 8703000 Service manual - Page 13
13
Kenmore 767. 8703000 Service manual - Page 14
14
Kenmore 767. 8703000 Service manual - Page 15
15
Kenmore 767. 8703000 Service manual - Page 16
16
Kenmore 767. 8703000 Service manual - Page 17
17
Kenmore 767. 8703000 Service manual - Page 18
18
Kenmore 767. 8703000 Service manual - Page 19
19
Kenmore 767. 8703000 Service manual - Page 20
20
Kenmore 767. 8703000 Service manual - Page 21
21
Kenmore 767. 8703000 Service manual - Page 22
22
Kenmore 767. 8703000 Service manual - Page 23
23
Kenmore 767. 8703000 Service manual - Page 24
24
Kenmore 767. 8703000 Service manual - Page 25
25
Kenmore 767. 8703000 Service manual - Page 26
26
Kenmore 767. 8703000 Service manual - Page 27
27
Kenmore 767. 8703000 Service manual - Page 28
28
Kenmore 767. 8703000 Service manual - Page 29
29
Kenmore 767. 8703000 Service manual - Page 30
30
Kenmore 767. 8703000 Service manual - Page 31
31
Kenmore 767. 8703000 Service manual - Page 32
32
Kenmore 767. 8703000 Service manual - Page 33
33
Kenmore 767. 8703000 Service manual - Page 34
34
Kenmore 767. 8703000 Service manual - Page 35
35
A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible click should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
COMPONENTS TEST PROCEDURE RESULTS
SWITCHES Check for continuity of the Door Door
(Wire leads removed) switch with an Ohm-meter open closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
NO
COM
NC
COM
NO
COM
INTERLOCK CONTINUITY TEST