Teltonika FM1110 User Manual
Download Operation & user’s manual of Teltonika FM1110 GPS, Gps tracker for Free or View it Online on All-Guides.com.
Brand: Teltonika
Category: GPS , Gps tracker
Type: Operation & user’s manual
Model: Teltonika FM1110 , Teltonika FM1120
Pages: 76
69
8.7 I/O parameters
I/O properties are additional data sources which are recorded along with usual GPS data.
8.7.1 I/O#1 property parameter (ID=1160)
Parameter defines I/O property value. Possible values: enabled (1), disabled (0).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
I/O#1 priority (ID=1161)
I/O#1 High level (ID=1162)
I/O#1 Low level (ID=1163)
I/O#1 logic operand (ID=1164)
I/O#1 averaging length (ID=1165)
S8
8.7.2 I/O#1 priority (ID=1161)
Parameter defines I/O property type of priority: 0 is low, 1 – high, 2 – panic.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
0
I/O#1 property parameter
(ID=1160)
I/O#1 High level (ID=1162)
I/O#1 Low level (ID=1163)
I/O#1 logic operand (ID=1164)
I/O#1 averaging length (ID=1165)
S8
8.7.3 I/O#1 High level (ID=1162)
Parameter defines high value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483647
2147483647
1
I/O#1 property parameter (ID=1160)
I/O#1 priority (ID=1161)
I/O#1 Low level (ID=1163)
I/O#1 logic operand (ID=1164)
I/O#1 averaging length (ID=1165)
S32
8.7.4 I/O#1 Low level (ID=1163)
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.