Thermador PO301 Service Manual

Download Service manual of Thermador POD301 Microwave Oven, Oven for Free or View it Online on All-Guides.com. This version of Thermador POD301 Manual compatible with such list of devices, as: POD301, POD302, PO301, PO302, PODC302

Thermador POD301 Service manual - Page 1
1
Thermador POD301 Service manual - Page 2
2
Thermador POD301 Service manual - Page 3
3
Thermador POD301 Service manual - Page 4
4
Thermador POD301 Service manual - Page 5
5
Thermador POD301 Service manual - Page 6
6
Thermador POD301 Service manual - Page 7
7
Thermador POD301 Service manual - Page 8
8
Thermador POD301 Service manual - Page 9
9
Thermador POD301 Service manual - Page 10
10
Thermador POD301 Service manual - Page 11
11
Thermador POD301 Service manual - Page 12
12
Thermador POD301 Service manual - Page 13
13
Thermador POD301 Service manual - Page 14
14
Thermador POD301 Service manual - Page 15
15
Thermador POD301 Service manual - Page 16
16
Thermador POD301 Service manual - Page 17
17
Thermador POD301 Service manual - Page 18
18
Thermador POD301 Service manual - Page 19
19
Thermador POD301 Service manual - Page 20
20
Thermador POD301 Service manual - Page 21
21
Service Manual for Thermador Professional Series Built-in Wall Ovens
4.15 Rotisserie Motor
LED1 communicates the left digit of the error code.
LED2 communicates the middle digit of the error code.
If the rotisserie does not turn with the door closed and the oven in a
rotisserie mode, replace the rotisserie motor (120V 12W).
LED3 communicates the right digit of the error code.
For example, Error Code 115 is displayed by 1 blink of LED1, 1 blink
of LED2, and 5 blinks of LED3. After a 1 second pause, the end of the
code series will be signaled by LED1, LED2, and LED3 turning on for
1 second. The sequence will then repeat.
The maximum weight allowed on the rotisserie spit is 12 lbs.
5 ERROR CODES
A Service Guide with error code information, wiring diagrams, and
instructions for entering Service Mode (if applicable) is packed with
every unit. Find it on the underside of the upper plenum access panel
as shown in Figure 19.
On models with digital display, digital error codes will show to the right
of the clock (see Figure 21), and blink at a frequency of 2 seconds on,
.5 second off. Clear the error by touching the + and buttons
simultaneously.
Figure 19 Location of Thermador Built-in Oven Service Guide
5.1 How Error Codes are Communicated
On models without a digital display, error codes are communicated
through a series of 3 LEDs on the User Interface (see Figure 20)
blinking at a frequency of .5 seconds on and .5 seconds off.
E115
TOUCH TO CLEAR ERROR
Figure 21 Error code 115 displayed on POD302/PODC302 user interface
5.2 Error Code Table
The following table is included in the PO302/POD302/PODC302
Service Guide. (The same error code information applies to
PO301/POD301/POM301/POMW301 models except for the E2xx
codes, which only apply to models with 2 cavities.)
Diagrams referenced in the table can be found in the appropriate
Service Guide.
1
CODE DESCRIPTION CAUSE/ACTION
E000 Wrong module combination Control module and user
interface are mismatched. Set
Option Code properly.
Figure 20 LEDs used to communicate error codes on the PO301 user interface (left)
and PO302 user interface (right)
3
2
1
2
3
Page 17 of 21