Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge the high voltage
capacitor before servicing, unless testing requires power.
©2004 Maytag Services 16023056 Rev. 0 25
Illustration Component Test Procedure Results
FTP Connector
TOP
1
2
3
4
5
6
7
8
9
10
11
12
13
Touch Pad/Control
Panel
Model AMV4204A**
Removal of Touch
Pad/Control Panel is
required to perform test.
Check for continuity.
When touched: Less than
400
When not touched: More
than 1 mega
Pad
1
2
3
4
5
6
7
8
9
0
Popcorn
Baked Potato
Beverage
Cook
Reheat
Poultry
Soften
Melt
Auto Defrost
Time Defrost
Rapid Defrost
Clock
Cook Time
Control Setup
Power Level
Add 30 Sec.
Hold Warm
Stop/Clear
Enter/Start
Custom Program
Kitchen Timer
Light Timer
Vent Hi/Lo/Off
Turntable On/Off
Light Hi/Lo/Off
Trace
8 & 1
8 & 2
8 & 3
8 & 4
8 & 5
8 & 6
8 & 7
13 & 5
13 & 6
13 & 7
11 & 1
9 & 6
9 & 7
11 & 2
11 & 3
10 & 4
10 & 6
10 & 7
11 & 4
11 & 6
11 & 7
12 & 5
9 & 2
12 & 1
13 & 1
11 & 5
12 & 2
13 & 3
13 & 4
9 & 3
12 & 4
9 & 5
10 & 1
12 & 3
10 & 3
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity